MOUNTING
4.3
Maximum permissible mounting tolerance when the Baumer Hübner K 35 spring
disk coupling is used
Encoders should be driven through the Baumer Hübner K 35 spring disk coupling (acces-
sory), that can be pushed onto the shaft without axial loading�
i
The figure below shows the version with EURO flange B10, the same maximum
permissible mounting tolerances are valid at version with housing foot B3�
)
The encoder must be mounted on the drive with the least possible angular error
and parallel misalignment�
)
Risk of damaging the ball bearings
Coupling components must not be driven onto the shaft with improper force (e� g�
hammer impacts), because of the risk of damaging the ball bearings�
Admissible
parallel misalignment
* For insulated hub version
All dimensions in millimeters, unless otherwise stated�
11/33
2-10
Admissible
angular error
MB245EN - 11171693, 17A2, Baumer_PMG10-SSI_II_EN
Admissible
axial movement