Baumer Hubner Berlin PMG 10 Panduan Petunjuk Pemasangan dan Pengoperasian - Halaman 12

Jelajahi secara online atau unduh pdf Panduan Petunjuk Pemasangan dan Pengoperasian untuk Konverter Media Baumer Hubner Berlin PMG 10. Baumer Hubner Berlin PMG 10 36 halaman. Absolute encoder with magnetic sensing
Juga untuk Baumer Hubner Berlin PMG 10: Panduan Petunjuk Pemasangan dan Pengoperasian (48 halaman)

Baumer Hubner Berlin PMG 10 Panduan Petunjuk Pemasangan dan Pengoperasian
MOUNTING / MOUNTING WITH HOUSING FOOT B3
4.2
Mounting with housing foot B3
4.2.1
Mounting the spring disk coupling to the encoder
We recommend using the Baumer Hübner spring disk coupling K 35, see
page
11, available as accessory� When other couplings are used pay attention to
manufacturer's notes�
7
M
= 100 Ncm
t
4.2.2
Mounting to drive shaft
)
Lifetime restrictions and angle error by radial deviations
High runout of the drive shaft can cause encoder angle error�
High runout of the drive shaft can cause vibrations, which can shorten the lifeti-
me of the encoder�
» Lubricate drive shaft!
» Minimize drive shaft runout (≤0.2 mm; ≤0.03 mm recommended).
i
The encoder must be mounted with cable connection facing downward and not
exposed to water�
9/33
2�5 mm
MB245EN - 11171693, 17A2, Baumer_PMG10-SSI_II_EN
section 4.3,