Baumer Hubner Berlin PMG 10 Installation And Operating Instructions Manual - Page 12

Browse online or download pdf Installation And Operating Instructions Manual for Media Converter Baumer Hubner Berlin PMG 10. Baumer Hubner Berlin PMG 10 36 pages. Absolute encoder with magnetic sensing
Also for Baumer Hubner Berlin PMG 10: Installation And Operating Instructions Manual (48 pages)

Baumer Hubner Berlin PMG 10 Installation And Operating Instructions Manual
MOUNTING / MOUNTING WITH HOUSING FOOT B3
4.2
Mounting with housing foot B3
4.2.1
Mounting the spring disk coupling to the encoder
We recommend using the Baumer Hübner spring disk coupling K 35, see
page
11, available as accessory� When other couplings are used pay attention to
manufacturer's notes�
7
M
= 100 Ncm
t
4.2.2
Mounting to drive shaft
)
Lifetime restrictions and angle error by radial deviations
High runout of the drive shaft can cause encoder angle error�
High runout of the drive shaft can cause vibrations, which can shorten the lifeti-
me of the encoder�
» Lubricate drive shaft!
» Minimize drive shaft runout (≤0.2 mm; ≤0.03 mm recommended).
i
The encoder must be mounted with cable connection facing downward and not
exposed to water�
9/33
2�5 mm
MB245EN - 11171693, 17A2, Baumer_PMG10-SSI_II_EN
section 4.3,