DPI Xcel 7QP-12F950P25-C00 Manual - Halaman 5

Jelajahi secara online atau unduh pdf Manual untuk Pengisi Daya Baterai DPI Xcel 7QP-12F950P25-C00. DPI Xcel 7QP-12F950P25-C00 15 halaman. 10-channel/bank 6,8,12v battery charger

wired and in good electrical condition, and large enough for the AC rating of
charger as specified in this TABLE:
EXTENSION CORDS FOR BATTERY CHARGERS
Length of cord (feet):
AWG size of cord:
 Refer to the Product ID Label affixed to the product and identify the input
requirements such as '120Vac, 60Hz, 10Amps'. Ensure that the product will
be connected to a matching utility power rating. For example; if product is
rated at 60Hz, do not connect to a 50Hz utility.
 Do not connect product to AC receptacles that share power with any other
moderate to heavy loads such as air conditioners, motors and other common
appliances. Most appliances turn on/off at random and cause power surges
and power droops that can severely affect the product connected to that
same power circuit.
 Inspect AC Receptacles for general wear, including loose or hanging
receptacles and be very aware of potentially worn contacts. If any heat is felt
in and around the receptacle while the charger is operating, this is an
immediate indication of danger caused by a worn receptacle.

4. SAFE GROUNDING INSTRUCTIONS

 Do not remove Ground Pin from charger's Power Supply AC Plug, or connect
to utility power via an adaptor that bypasses the product's ground pin
connection. The product must be grounded at all times when connected to
utility power.
 This battery charger's Power Supply must be grounded to reduce the risk of
electric shock. The Power Supply is equipped with an AC cord set having an
equipment-grounding conductor. This AC cord set must be connected to an
appropriate receptacle that is properly installed and grounded in accordance
with the National Electrical Code and all local codes and ordinances.
WARNING: IMPROPER CONNECTION OF THE EQUIPMENT-
GROUNDING CONDUCTOR CAN RESULT IN A RISK OF AN ELECTRIC
SHOCK.
 The conductor with insulation having an outer surface that is green, with or
without yellow stripe(s), is the equipment-grounding conductor. If repair or
replacement of the charger's AC cord set is necessary, refer to a qualified
service agent, and do not connect the equipment-grounding connector to a
live terminal.

5. PREPARING TO CHARGE

WARNING: The product's supplied Power Supply is matched to the
Charger Power Requirements and may only be replaced with a
Manufacturer's Approved Power Supply.
RECOMMENDED MINIMUM AWG SIZE FOR
25
50
18
18
5
100
150
18
18