AMS Controls MP328CL Panduan Referensi - Halaman 4

Jelajahi secara online atau unduh pdf Panduan Referensi untuk Pengontrol AMS Controls MP328CL. AMS Controls MP328CL 17 halaman. Closed loop backgauge controller

AMS Controls
5/23/2012
The SETUP mode is used when the MP328CL is initially installed
to configure it to the particular characteristics of the Gripper. The
SETUP mode is entered by pressing the "Set Up" key and the
mode can be exited by pressing the "∗" key. When power is
applied to the controller, the built-in diagnostics check the
memory for data retention.
If an error is detected, the memory is automatically cleared and
the SETUP mode is entered to indicate that this data should be
reentered. The setup values are entered in the order shown
below and an explanation of each parameter is given. A form is
provided in the back of this manual for recording the setup
parameters of your machine. This form should be completed
after your machine has been installed and properly adjusted.
To enter the SETUP mode, press the "Set Up" key.
following display will appear.
1=Configure
Selec
3=Loc/Remote
ting
"1"
will allow the operator to adjust the following parameters:

Reference Mode

The REFERENCE MODE parameter tells the MP328CL where
the reference switch is located. The reference point is the center
of the brake where the bend occurs. If the switch is close to the
reference point and most of the moves of the Gripper occur
"behind" the switch, the REFERENCE MODE is NEAR. If the
switch is behind the Gripper and most of the moves are in "front"
of the switch, the REFERENCE MODE is FAR. Use any number
key to toggle the choices.
The switch for a NEAR REFERENCE MODE must be normally
closed and remain open as long as the Gripper is on the switch
or closer to the reference point than the switch. The switch for a
FAR REFERENCE MODE must be normally open and remain
closed as long as the Gripper is on the switch or farther away
from the reference point than the switch.
4
MP328CL Controller
The
2=In/Out
4=Reference
Gripper