Juga untuk Bosch 800 Series: Panduan Petunjuk Instalasi (24 halaman), Panduan Instalasi (40 halaman), Panduan Penggunaan dan Perawatan (12 halaman), Panduan Instalasi (23 halaman), Panduan Instalasi (28 halaman), Panduan Instalasi (32 halaman), Buku Petunjuk (32 halaman), Panduan Instalasi (32 halaman), Panduan Memulai Cepat dan Keselamatan (7 halaman), Panduan Penggunaan dan Perawatan (40 halaman), Panduan Instalasi (40 halaman), Panduan Instalasi (32 halaman), Panduan Petunjuk Instalasi (40 halaman), Panduan Instalasi (48 halaman), Panduan Penggunaan dan Perawatan (33 halaman), Panduan Penggunaan dan Perawatan (49 halaman), Panduan Memulai Cepat (7 halaman), Panduan Memulai Cepat dan Keselamatan (13 halaman), Panduan Instalasi (32 halaman), Panduan Servis (36 halaman), Panduan Penggunaan dan Perawatan (24 halaman), Panduan Penggunaan dan Perawatan (40 halaman), Panduan Petunjuk Instalasi (28 halaman)

Bosch 800 Series Panduan Petunjuk Instalasi

Drain Connections

The dishwasher drain hose may be connected to the house-
hold or field drain plumbing in one of four ways. You will need
a 1¼" diameter hole in order to pass the drain hose through
the cabinet.
1 Directly under the sink dishwasher drain connection, as
shown in Figure 9.
2 Directly to a disposer dishwasher drain connection, as
shown in Figure 10.
3 To the under sink dishwasher drain connection through
an air gap, as shown in Figure 11.
4 To a disposer dishwasher drain connection through an air
gap, as shown on Figure 12.
IMPORTANT NOTES:
· If local ordinance require an air gap, install it according
to the manufacturer's instructions.
· If the dishwasher drain hose is to be connected to a
disposer dishwasher drain connection, remove the plug
from the disposer's dishwasher drain connection.
· The dishwasher drain hose must have one place along
its length that is securely attached 20" (508 mm) above
the cabinet floor.
· The drain hose length can be extended if necessary. The
maximum length of the drain hose, including the hose
leading to the air gap, is 150" (3800 mm).
10
Figure 8
Figure 9
Non-Metallic Tie
MIN.
20"
G
Figure 11
G
Figure 10
Non-Metallic Tie
MIN.
20"
G
Figure 12
Remove
plug
G
10