Installation instruction GatorSignal Plus

6 Technical data

Technical data
Input voltage
Current consumption
Reference for the following operating modes (Gator 2000/RO):
* No relay of the outputs power supplied, power supply exclusively via mains adapter, only one lock and input unit.
** All output relays activated, both inputs power supplied (consumption via power supply of the system), only one lock and
input unit.
Power supply lock system
Measurements
Weight
Input
Outputs
Screw terminals clamping strip
Switching capacity release contact
Operating temperature
Humidity tolerance
Protection
Environmental class
VdS security level
12VDC, controlled
<
4 mA*
<105 mA**
add. bolt load depending current consumption of locks,
display lighting etc.
The supply of all other components from the signal box is
achieved indirectly by bus cables.
max. 2 x 2A (ca. 10 VDC)
max. 1 x 2A (3,3 VDC)
85 x 85 x 25 mm
90 g
2 x optocoupler input
max. 12 VDC, ca. 10mA
3 x relay output
Changeover contact, rated switching capacity 2 A, 30 V
(ohmic load)
AWG 28 -16
Skinning length 5 mm
2 A, 30 V (ohmic load)
0 bis +50° C
up to 75 % relative humidity
IP 30
II by VdS
C