Carl Wittkopp GatorSignal Plus Instruksi Instalasi - Halaman 3
Jelajahi secara online atau unduh pdf Instruksi Instalasi untuk Peralatan Perekaman Carl Wittkopp GatorSignal Plus. Carl Wittkopp GatorSignal Plus 8 halaman.
Installation instruction GatorSignal Plus
3.1.2 Ouptuts
Bolt position
Opening delay active
Release window active
Opening window active
4 Plug position
All locks within the Gator series are equipped with an 8-pin plug to connect to the "GatorSignal Plus" box.
4.1 Gator 2000
4.3 Gator 5000
GatorSignal Plus (8-pin)
Connect the cable to the according plug for the "Gator Signal Plus" box.
GatorSignal Plus (8-pin)
For signalling the lock's bolt position. The contact is active
when the bolt reaches or leaves the closed position.
Note:
If the bolt position should change while the lock is in
standby mode, i.e. with latch bolt locks, the switching
status changes only when the lock is active again.
Silent alarm – By entering the alarm code (last code
number freely adjustable) an alarm signal is triggered and
sent to the burglar alarm system. The lock opens with the
alarm code.
When the opening delay is started the according output
is triggered. The signal can be used for signal lights for
example.
If an opening delay is activated, the according output is
switched. The signal can then be used for i.e. signal lights.
The lock can be opened after the opening delay has en-
ded. This is signaled by the according output.
4.2 Gator 3000/3010
4.4 Gator 6000/8000/9000
GatorSignal Plus (8-pin)
GatorSignal Plus (8-pin)
3