1 Notes

• Please read these instructions carefully before operating the lock.

1.1 Liability notes

• The installation of this signal box has to be done according to these instructions
• The installation instruction is part of VdS certification and the certification of other testing institutes.
• Non-compliance leads to the loss of this certification.
• When operating beyond the specifications the warranty of the manufacturer will be void.
• Take care of not damaging the cables and all connected components.

2 Introduction

• The connection box "GatorSignal Plus" is a universal interface for exchanging signals of locks within the Gator series with
external systems via potential-free contacts. This includes the function as blocking device and the signalization of a silent
alarm.
• It offer the possibility of power supplying a lock system (containing of several locks and/or input units).
• Up to two locks or locking electronics can be connected to one box. Inside of redundant locks there are two independent
electronics. They work as two separate locks.

3 Signals

• The following signals can be processed or generated independently from the configuration
• Concerning the adjustment of signals of pre-defined levels 10, 20, 30 we refer to the "General operating notes levels 10,
20, 30".

3.1 In-/outputs

• Every lock electronic has got 3 outputs and 2 inputs. The assignment is generally freely configurable and is done via PC
software Gator Select. For the standard configurations (level 10, 20, 30) they are already configured.
• The signals on the input take effect on both connected locks/lock electronics. In that manner a boltwork switch can be pro-
cessed by two electronics at the same time.
• With two connected lock electronics one output each is connected if at least one has the condition "disjunction".

3.1.1 Inputs

Release contact [blocking device]
Start delay time
Boltwork switch
Blocking signal
2
Installation instruction GatorSignal Plus
System will be blocked when the according controlling
input has got control voltage.
When changing the signal level from the defined idle
state, the delay time 1 is started.
Automatic closing is interrupted until the boltwork is in
closed position. This ensures that the bolt of motor locks
can go into closed position without taking damage.
With an active signal the lock cannot be closed via the
input unit.
The automatic closing is not affected by it.