To modify the correction factor in field follow this procedure
1
Wait for the meter to go standby.
2
Reset the resettable total.
3
Start dispensing into a measuring glass.
Stop dispensing when over 5 Litres of volume is reached, read out
the actual value. The volume that is displayed on the LCD is the
Display Value, not the Actual Value which may be slightly higher.
For example, in the figure on the right, the Display Value is 18.96
while the Actual Value is 20.75.
4
Press the MOVE key. Keep it pressed until it shows as the right
fig., with the digit flashing in
go the next digit so that the Actual Value can be input.
5
Make sure the correction factor is right and then press the
MOVE key. Keep it pressed until calibration is finished and the
factor is save. The meter will then return to be on standby.