Carolina UltaSpot Buku Petunjuk - Halaman 2
Jelajahi secara online atau unduh pdf Buku Petunjuk untuk Lampu Banjir Carolina UltaSpot. Carolina UltaSpot 4 halaman.
1.
The pole and crossarms must be braced so that they are both
LEVEL (parallel) with the ground.
2.
Each floodlight is attached to the crossarm(s) so that the glass
lens is LEVEL(parallel) with the ground.
3.
An inclinometer is positioned on the glass lens perpendicular
to the crossarm. The down angle adjustment that is indicated
in the square boxes of the fixture arrangement and aiming
schedule is made. The bolts that attach the trunnion to
floodlight housing are tightened.
4.
The reposition stop is then aligned against its stop and secured
by tightening the screw.
5.
The bolts are then loosened and the floodlight is rotated back
to its original horizontal (level) position in preparation for Left
or Right adjustment. Retighten the bolts.
6.
The inclinometer is positioned on the glass lens parallel to the
crossarm. The crossarm attachment bolts are loosened, the
Left or Right angle adjustment is made, and the bolt is
retightened.
7.
Finally, the trunnion/fixture bolts are loosened and the
floodlight is rotated to its final vertical position (against the
reposition stop). Make sure that the stop is not bent by rapid
movement during rotation. Securely tighten all bolts and
screws.
ADDITIONAL SAFETY NOTES
1.
High Intensity Discharge (HID) lamps contain mercury and
should be disposed of in accordance with Federal, State and
Local codes.
2.
HID lamps operate at temperatures above 200C, lamps should
be allowed to cool to ambient temperature prior to handling.
3.
This luminaire is a high wattage, high voltage piece of
equipment. There is a RISK OF ELECTRICAL SHOCK when
working on this product. Installation, service and maintenance
should be conducted by properly trained personnel only.
4.
Do not fuse the incoming ground or neutral line to the
luminaire; this can cause electrical shock and death.
5.
Do not modify or retrofit this product without the express
authorization of CHM.
CLEANING AND MAINTENANCE
1.
The UltaSpot optic is fabricated of advanced, highly reflective
aluminum panels. The surface is extremely robust though care
should be taken to avoid damage to the surface and reduction
in product efficiency. Prior to cleaning, any surface
contaminates should be gently removed with a clean lint free
microfiber cloth to avoid abrasion during cleaning. The surface
should be gently cleaned with a highly diluted soap (dish soap)
and non-iodized water mixture. After cleaning, the surface
shall be rinsed with clean non-iodized water and a new, clean
microfiber cloth. The optic should remain open until the
reflective surface is completely dry.
2.
Like the reflector, the glass utilized in the UltaSpot has an
advanced, high efficiency coating. The glass can be cleaned
with a typical glass cleaner (e.g. Windex) though under no
circumstance should the glass be cleaned with paper towels.
Utilize a clean lint free microfiber towel to clean the glass
surfaces.
The included installation instructions are not to be considered to cover all details. General best practice and safety precautions should be taken when working with
electrical equipment such as this. Should there be any uncertainty about the guidelines contained herein, Carolina High Mast or an Carolina High Mast
representative should be contacted immediately for further guidance.
Document Revision 07/18/14
INSTRUCTIONS
UltaSpot FLOOD LIGHT
3.
Luminaires should be group relamped at the end of the rated
useful life of the lamp. It is recommended that cleaning occur
during relamping.
4.
Replacement lamps should be of the same make and model as
shipped with the original luminaire.
5.
To ensure the UltaSpot Luminaire performs at maximum
efficiency throughout the product life, consult Carolina High
Mast during repair to ensure replacement parts have been
approved by CHM.