INSTALLATION AND OPERATION MANUAL
FIGURE 11 – DATA CONNECTIONS
– Data In/Out
+ Data In/Out
– Data Out
+ Data Out
RS232 Out
RS232 In
GND
FIGURE 12 – DATA SETTINGS
Data Transmit
RS232
Data Receive
Signal Ground
Data Out (+)
Data Out (–)
RS422
Bi-phase or
Data Out (+)
Manchester
Data Out (–)
2-Wire
RS485
Data Out (A)
Data Out (B)
4-Wire
RS485
TECH SUPPORT: 1.888.678.9427
Customer
Equipment
Signal – Pin
OUT – 3
GND – 1
Signal – Pin
+IN/OUT – 6
–IN/OUT – 7
Data In (+)
+OUT – 4
Data In (–)
–OUT – 5
Signal – Pin
+IN/OUT – 6
–IN/OUT – 7
Signal – Pin
Data (A)
+IN/OUT – 6
Data (B)
–IN/OUT – 7
Signal – Pin
+IN/OUT – 6
–IN/OUT – 7
Data In (A)
+OUT – 4
Data In (B)
–OUT – 5
FDX60
IN – 2
FDX60
FDX60
FDX60
FDX60
FDX60(M)(S)(-M)
Customer
FDX60
Equipment
Signal – Pin
OUT – 3
Data Receive
IN – 2
Data Transmit
GND – 1
Signal Ground
FDX60
Signal – Pin
+OUT – 4
Data In (+)
–OUT – 5
Data In (–)
+IN/OUT – 6
Data Out (+)
–IN/OUT – 7
Data Out (–)
FDX60
Signal – Pin
+OUT – 4
Data In (+)
–OUT – 5
Data In (–)
FDX60
Signal – Pin
+IN/OUT – 6
–IN/OUT – 7
FDX60
Signal – Pin
+OUT – 4
Data In (A)
–OUT – 5
Data In (B)
+IN/OUT – 6
Data Out (A)
–IN/OUT – 7
Data Out (B)
Data (A)
Data (B)
INS_FDX60_REV–
04/23/10
PAGE 7