—Consult the dealer or an experienced radio/TV technician for help.
17. Medical AC adapter which output is DC 6.0V 600mA and complied with IEC 60601-1/EN
60601-1/UL 60601-1 and IEC 60601-1-2/EN 60601-1-2/UL 60601-1-2 is suitable for this
monitor. Please note that the monitor jack size: hole Φ5.5mm, center pin Φ2.0mm. Please
pay attention to polarity.
18. Measurements are not possible in patients with a high frequency of arrhythmias.
19. The device is not intended for use on neonates, children or pregnant women. (Clinical
testing has not been conducted on neonates, children or pregnant women.)
20. Motion, trembling, shivering may affect the measurement reading.
21. The device would not apply to the patients with poor peripheral circulation, noticeably low
blood pressure, or low body temperature (there will be low blood flow to the measurement
position).
22. The device would not apply to the patients who use an artificial heart and lung (there will
be no pulse)
23. Consult your physician before using the device for any of the following conditions:
common arrhythmias such as atrial or ventricular premature beats or atrial fibrillation,
arterial sclerosis, poor perfusion, diabetes, pre-eclampsia, enal diseases.
SETUP AND OPERATING PROCEDURES
1. DOWNLOAD THE FREE APP
Prior to first use, download and install the Andon App from the App Store(iOS device) or
Google Play(Android device). Use keyword search terms "mHealth".
2. BATTERY LOADING AND AC ADAPTER LOADING
a. Open battery cover at the back of the monitor.
b. Load four "AA" size batteries. Please pay attention to polarity.
c. Close the battery cover.
When LCD shows battery symbol , replace all batteries with new ones.
Rechargeable batteries are not suitable for this monitor.
Remove the batteries if the monitor will not be used for a month or more to avoid
relevant damage of battery leakage.
Avoid the battery fluid to get in your eyes. If it should get in your eyes, immediately
rinse with plenty of clean water and contact a physician.
d. If you use the AC adapter, please make sure the monitor turn off or no batteries. Put
the connector plug of the adapter into the socket as the picture, Then plug the adapter
to AC outlet. When disconnect the AC Adapter:
Remove the AC Adapter from the electrical outlet;
Remove the AC Adapter plug from the monitor socket.
Do not plug or unplug the power cord into the electrical outlet with wet hands.
Do not overload power outlets. Plug the device into the appropriate voltage outlet.
If the AC adapter is abnormal, please change the adapter.
Do not pull out the adapter when you are using the monitor.