Electrolux DF 6160 Panduan Pengoperasian dan Instalasi - Halaman 13
Jelajahi secara online atau unduh pdf Panduan Pengoperasian dan Instalasi untuk Kap Ventilasi Electrolux DF 6160. Electrolux DF 6160 20 halaman. Cooker hood
Juga untuk Electrolux DF 6160: Petunjuk Pengoperasian dan Pemasangan (22 halaman)
Installation
Preparing the wall unit - Extractor version
• The hood is supplied as an
extractor unit.
Before installing the hood, drill a
hole in the roof of the wall unit
(see Fig. 5). This hole is to allow
passage of the outlet pipe and the
power cable, and to facilitate
servicing.
• The wall unit must have a
minimum body depth (without
door) of 300 mm with recessed
light screen and min. 370 mm with
flush-mounted light screen. The unobstructed internal height must
be at least 370 mm.
Preparing the wall unit - Filter version
• Before installation of the hood in the wall unit, a 115x115 mm hole
for the deflector should be cut in the ceiling of the wall unit. Fig. 6-7.
• Depending on the wall unit height, you need for return air operation
a pipe union or additionally a non-flammable length of pipe (Ø 100/
115/120 mm) as far as the ceiling of the wall unit.
Fig. 6
Fig. 5
Fig. 7
13