Section 4: Component Removal
PCB Board Control Removal
NOTE
1. Cut off power to the hood unit.
2. The vent grill cover, filter assembly and control
box top cover needs to be removed before the
PCB control board can be removed
3. Wear a anti static wrist strap.
1. Remove two screws on the electrical
mounting plate wire strain relief. Remove
strain relief.
2. Remove all the terminals on the PCB
control board. Note the location and color
of the harness connectors on the PCB
control board for reassembly.
4-7
3. Spread the plastic retaining clips to release the
PCB control board from electrical mounting plate.
NOTE
1. Reinstall PCB board and reconnect the
terminals into the sockets according to the
connector color and number of pins.
2. After reinstalling the control box top cover
(before tightening screws) check that all
wires are inside control box top cover. No
wires should be pinched between the top
cover and range hood housing.
3. After the unit has been completely
reassembled run the hood and check all
functions.