3M G5 Manual - Halaman 7
Jelajahi secara online atau unduh pdf Manual untuk Headset 3M G5. 3M G5 10 halaman. Drive-thru systems
Juga untuk 3M G5: Panduan Referensi Cepat (2 halaman), Buletin Teknis (6 halaman), Buletin Teknis (2 halaman), Panduan Memulai Cepat (3 halaman), Buletin Teknis (12 halaman), Manual (8 halaman)
5. Timer Greet Event.
Currently The Greet Event (for a Timer) is extracted from the XT-1 Basestation using any one of the following procedures.
a. Using
and GND on the XT-1 Basestation
b. Using a combination of XT-1 Basestation's
--
rd
-- 3
Detector Relay on top of the XT-1 Basestation and
-- The Auxiliary Relay #3 and it's COM
c. Using XT-1 Basestation's Menu Board Speaker terminals (MEN SKR+ and MEN SKR-)
To extract the Greet Event from the G5 Basestation, connect the wires from the Timer system to GPIO11 and GND1 as illustrated.
NOTE: GENERAL PURPOSE INPUT / OUTPUTs (GPIOs):
The G5 Basestation provides 16 configurable logical Inputs and Outputs.
All Inputs and Outputs are Active Low and are factory set to the following signals.
You can reassign any of these GPIOs to output or take as input a different signal via Digital IO Setup in the System Menu
7
and GND
To Timer System