Dry Air TECHNO PRO 5000 Panduan Pemilik - Halaman 10
Jelajahi secara online atau unduh pdf Panduan Pemilik untuk Dehumidifier Dry Air TECHNO PRO 5000. Dry Air TECHNO PRO 5000 11 halaman. Dry air techno pro 5000 dehumidifier
Techno Pro Component Wiring to Terminal Block
120V
TB1
L2= common terminals
Pwr = power terminals
L1 = 120V supply voltage terminals
TB = terminal block
SW1= main on/off power switch
L1 connections = Power cord; Sw1 (on/off switch to HC Power Module)
Pwr connections = Humidity Control module; compressor; jumper to TB2
L2 connections = Power cord; HC power module; compressor; defrost control; fan; hot
gas solenoid; condensate pump; hour meter
TB2 = TB1 jumper; defrost control; *DC Com; hour meter; condensate pump; purge switch
* = defrost control com terminal, power supply for fan(NC) and hot gas solenoid(NO)
L1
Sw1
120V terminal ( terminal 3 on HC power module)
L2
Power Module common terminal (terminal 2 on HC power module)
Pwr
NO contact (on HC Control Module)
120V
COM (jumper from HC Power Module to HC Control Module)
L2
Pwr
L1
TB2
313 North Oak Street • Burlington WA 98322 USA
Phone: 360-755-9176 Fax: 360-755-9236
Toll Free from U.S. or Canada: 1-888-755-9176
Email:
TB1
Sw1
• www.dryairtech.com