Techno Pro Component Wiring to Terminal Block
120V
TB1
L2= common terminals
Pwr = power terminals
L1 = 120V supply voltage terminals
TB = terminal block
SW1= main on/off power switch
L1 connections = Power cord; Sw1 (on/off switch to HC Power Module)
Pwr connections = Humidity Control module; compressor; jumper to TB2
L2 connections = Power cord; HC power module; compressor; defrost control; fan; hot
gas solenoid; condensate pump; hour meter
TB2 = TB1 jumper; defrost control; *DC Com; hour meter; condensate pump; purge switch
* = defrost control com terminal, power supply for fan(NC) and hot gas solenoid(NO)
L1
Sw1
120V terminal ( terminal 3 on HC power module)
L2
Power Module common terminal (terminal 2 on HC power module)
Pwr
NO contact (on HC Control Module)
120V
COM (jumper from HC Power Module to HC Control Module)
L2
Pwr
L1
TB2