Anolis ArcPower 144 Panduan Pengguna - Halaman 6
Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Peralatan Pencahayaan Anolis ArcPower 144. Anolis ArcPower 144 20 halaman.
This device falls under protection class I.Therefore the ArcPower 144 has to be connected
to a mains socket outlet with a protective earthing connection.
4.2.Mounting the ArcPower 144
Flat surface
The ArcPower 144 should be be placed on a non-f lammable f lat surface in any orientation and fixed by the
four screws.There are 4 mounting holes of 5x7 mm in housing of the driver.
4.3 Conection cables
1. The adapter cable RJ45/XLR connects the ArcPower 144 to the DMX controller. If your DMX controller has
RJ45 socket for DMX output, use RJ45 patch cable for connection with the ArcPower 144.
RJ45 plug
View facing pins
Pin 1: Not used
Pin 2: Not used
Pin 3: Not used
Pin 4: Not used
Pin 5: +5V
Pin 6: Data +
Pin 7: Data -
Pin 8: GND
2. RJ45 patch cables category 5 that connect the ArcPower 144 each other are wired 1:1,
that is, pins with the same numbers are connected together.
Pin 1: Not used
Pin 2: Not used
Pin 3: Not used
Pin 4: Not used
Pin 5: +5V
Pin 6: Data +
Pin 7: Data -
Pin 8: GND
Screws
DMX 512 XLR plug (male)
Front view of the plug
Pin 1: GND
Pin 2: Data -
Pin 3: Data +
Pin 4: Not used
Pin 5: Not used
Pin 1: Not used
Pin 2: Not used
Pin 3: Not used
Pin 4: Not used
Pin 5: +5V
Pin 6: Data +
Pin 7: Data -
Pin 8: GND
6
Screws
Mounting holes