DSPM UniMeasure HX-VP510 Series Panduan Instalasi - Halaman 3
Jelajahi secara online atau unduh pdf Panduan Instalasi untuk Transduser DSPM UniMeasure HX-VP510 Series. DSPM UniMeasure HX-VP510 Series 3 halaman.
HX-VP1010 Series Installation Guide
Model HX-VP1010
Model HX-VP1010-xx-
Position
See Table 1 at right for position input voltage.
Velocity
The tachometer is self energizing and requires no input
RANGE
Note: Dimensions in
2", 10"
brackets are millimeters.
3", 15", 30"
4", 20", 40"
5", 25", 50"
60"
80"
Alternate Wire Rope Exit
E1
Via Paolo Uccello 4 - 20148 Milano
Tel +39 02 48 009 757 Fax +39 02 48 002 070
Wiring and Circuit Diagram
Position
Excitation Voltage ........ +15 & -15 VDC (±5%)
Output Impedance ....... 1.0 Ω max.
Output Load ................. 5KΩ min.
Velocity
The tachometer is self energizing and
requires no input voltage.
Option
Designator
Voltage
SI
4.9 to 30 VDC
SI5
5 ±0.5 VDC
SI12
12 ±0.5 VDC
SI15
15 ±0.5 VDC
SI24
24 ±1.0 VDC
Dimensional Information
NOTE
Mount with Ø.25 or M6
Socket Head Cap Screws.
Alternate Wire Rope Exit
"A"
"B"
"C"
1.12 (28.4)
1.79 (45.5)
1.21 (30.7)
.96(24.4)
1.95 (49.5)
1.37 (34.8)
.80 (20.3)
2.11 (53.6)
1.53 (38.9)
.64 (16.3)
2.27 (57.7)
1.69 (42.9)
.49 (12.4)
2.42 (61.5)
1.84 (46.7)
.25 (6.4)
2.66 (67.6)
2.08 (52.8)
E2
E3
With small blade type screwdriver (.105" max. blade
width X .023" max. blade thickness), adjust the Zero
and Span controls on the transducer to set the zero
and maximum output voltages. Note: The Zero and
Span controls are somewhat interactive and may re-
quire several iterations to obtain the desired zero and
maximum voltage settings. Extend the transducer cable
(on angular position transducers, rotate shaft) to the
desired zero position (must be within 10% to 90% of
Input
the total range). Adjust the Zero control to give a zero
voltage output. Then extend the cable (on angular posi-
tion transducers, rotate shaft) to the desired maximum
position in the direction of longest possible travel (either
positive or negative) from the zero position. To obtain
maximum output voltage magnitude this position must
lie within 50% to 100% of the longest possible travel.
Adjust the Span control to the output voltage magnitude
required (+ or - 10 VDC maximum). Recheck the zero
and span settings and readjust if necessary.
NOTE
Mount with Ø.50 or M12 Socket Head Cap Screws.
Alternate Wire Rope Exit
[email protected] www.dspmindustria.it