Attwood 4640 Petunjuk Instalasi - Halaman 2

Jelajahi secara online atau unduh pdf Petunjuk Instalasi untuk Pompa Air Attwood 4640. Attwood 4640 2 halaman. Tsunami aerator pump

LIVEWELL CONNECTION INSTRUCTIONS
See Accessories Chart for sizes / part numbers of Outlet Hose and
Spray Head.
1. Connect outlet hose from the aerator outlet fitting to the Spray
Head. Use a hose clamp at each end of the hose. (Figure 3)
IMPORTANT: Route the hose as straight as possible with an upward
angle. Avoid dips or sharp bends that can create airlock and hinder
water flow.
2. An aerator pump can be connected to the bottom of a livewell to
recirculate water within the tank.
Figure 3
Intake
WIRING INSTRUCTIONS
The power source to the pump must be a 12-volt DC battery ONLY.
Protect circuit with fuse (see chart) and make all wire connections
above the highest possible water level, using marine grade wire
connectors only. Waterproof all connections with suitable materials.
(Figure 4)
CAUTION: Failure to make waterproof connections and fuse pump
properly will void the product warranty.
Figure 4
Fuse Holder
2-Terminal
On/Off Switch
Brown Wire
Aerator
Spray Head
Smooth-Bore
Reinforced Hose
72" (183cm) Max. Length
From (+) Terminal to Fuse
Black Wire
(neg)
(pos)
12 Volt DC
(Power Source)
CARE AND MAINTENANCE
WARNING
If Aerator is installed thru-hull, BOAT MUST BE OUT OF THE
WATER to remove or replace aerator motor cartridge.
1. With boat out of water, occasionally remove Motor Cartridge and
check pump to be certain debris is not restricting or jamming the
impeller. Hold outlet with one hand and depress red locking tab
with other. Twist Motor Cartridge counter-clockwise and remove
from housing. (Figure 5)
Figure 5
Motor Cartridge
Unlock
Lock
Red Tab
"O" Ring
2. Be sure "O " ring is not damaged, nicked or worn. Lubricate the
"O " ring area with vegetable oil to ease re-assembly.
3. To install new Motor Cartridge (H), see Accessories Chart for
part number. Motor must match housing color: 500 Series = RED,
800 = BLUE, 1200 = GRAY.
4. Align motor cartridge red tab with slot on aerator housing. Push in
and turn clockwise.
WARNING
To avoid leaking or sinking, the RED TAB MUST BE LOCKED AND
EXTENDING through aerator housing slot.
ATTWOOD AERATOR PUMPS LIMITED WARRANTY
This Attwood Aerator Pump carries a three (3) year warranty. See
product catalog or www.attwoodmarine.com for details.
©2003 Attwood Corporation
1016 N. Monroe Street, Lowell, MI 49331-0260 www.attwoodmarine.com
Red Tab
Must Be Extending Thru Slot