High voltage wiring

First of all, read
"LIABILITY AND SAFE USE OF THIS
UNIT". The wiring of the high voltage must be carried
out by a specialist. Keep in mind that DC high voltage is very dangerous and deadly.
Wait for the discharge time before disconnecting the high-voltage connectors.
Wait minimum 6 minutes
after switch off the DC voltage.
Use a shielded wire with appropriate shielding points. The AC-side wires must only be connected to the
ground at the motor side. The wires should be as short as possible and as close to each other as possible.
This way the inductance of the wire can be minimized. Please read the CP-600 connector user manual
before use CP-600 connectors
High voltage and low voltage must be electrically isolated. The isolation monitor monitors the isolation
existence. If the monitor detects any error, must turn off the high voltage system.
First install the low voltage part separately and test the peripherals. Use current control mode in the App
Setting/Analog I/O / Analog Input Functions for first testing
The figure illustrates the minimum elements of a high voltage system.