DTI HV-500 Deskripsi Teknis - Halaman 7

Jelajahi secara online atau unduh pdf Deskripsi Teknis untuk Inverter DTI HV-500. DTI HV-500 18 halaman.

DTI HV-500 Deskripsi Teknis
HV-500 TECHNICAL DESCRIPTION
(BETA
VERSION)

EFFICIENCY

The efficiency of the system is influenced by many factors. In order to achieve good efficiency, the voltage
difference between inverter AC and DC must be taken into account. Lower voltage difference, means
better efficiency. The AC voltage is determined by the motor-generated voltage. This value is directly
proportional to the motor speed.
In addition, the AC current, the switching frequency, and the AC frequency have a significant effect on
efficiency.
We used an medium voltage EMRAX 228 motor with high 660 Vdc for efficiency measurement.
7
Revision 1.31