TH106, TL6160 PROGRAMMABLE THERMOSTAT
8. Power Outage
During a power outage, LP (Low Power) appears for the first
minute. Then the screen becomes blank. The settings are
stored in memory. After initial installation, product must be
connected to power for a minimum of two hours to enable
the power outage feature. However, if the power failure
exceeds 4 hours, the thermostat's clock must be re-adjusted
and, if you are using the automatic Daylight Savings Time
changeover function, it must be re-enabled. When power
returns, the thermostat will return to the mode of operation
active prior to the power failure.
9. Troubleshooting
Problem
Thermostat is hot.
Under normal operation, the
thermostat housing can reach a
temperature between 95°F (35°C) and
104°F (40°C).
LO is displayed.
The measured temperature is below
the display range. Heating is activated.
HI is displayed.
The measured temperature is above
the display range.
Wrong temperature
The thermostat is exposed to air draft.
is displayed.
Eliminate the draft. The sticker on the
thermostat's screen has not been
removed.
Wrong time is
The thermostat was without power for
displayed.
more than 4 hours.
Temperature does
Check that the thermostat is in
not change
Automatic mode. Check the schedule
according to the
and clock settings.
programmed
schedule.
LP appears on the
The thermal circuit breaker in the
screen or the screen
heater is opened. This can happen if
is blank despite
the heater is obstructed by furniture or
there is no power
curtain and has overheated, or if the
outage.
thermal circuit breaker is defective.
Display looks faded
The heating system is less than the
when heating is
required minimum load. This
activated
thermostat cannot be used below that
rating.
The settings cannot
The settings are locked (see section
be changed.
3).
E2 is displayed
The thermostat performance is
reduced due to a sensor error. Please
contact technical support for more
information.
69-2202—07
Solutions
10. Technical Specifications
Power:
120/240 VAC, 60 Hz
Minimum load:
2 A (resistive only)
250 W @ 120 VAC
500 W @ 240 VAC
Maximum load:
16.7 A (resistive only)
2000 W @ 120 VAC
4000 W @ 240 VAC
Display range:
32°F to 140°F (0°C to 60°C)
Display resolution:
1°F (0.5°C)
Setpoint range:
40°F to 86°F (5°C to 30°C)
Setpoint interval:
1°F (0.5°C)
Storage:
-4°F to 120°F (-20°C to 50°C)
Approval:
c UL us