Auber Instruments SYL-1615SYS-W Panduan Cepat - Halaman 2

Jelajahi secara online atau unduh pdf Panduan Cepat untuk Pengontrol Suhu Auber Instruments SYL-1615SYS-W. Auber Instruments SYL-1615SYS-W 2 halaman. Charcoal smoker controller

Press V key to change the display to END. Then, press SET to exit. You can also ignore the steps after confirmation of
SV. The controller will return to normal operation mode if no key is pressed for 1 minute. Figure 2 is a detailed flow chart
that shows how to set the SV.
6)
Set the alarms.
The controller offers two alarms that can be set to turn on the buzzer at specific temperatures. The first alarm is controlled
by parameter AH1 and AL1. The initial setting will turn on the buzzer at 250° F and off when temperature drops below
249° F. The second alarm is controlled by parameter AH2 and AL2. The initial setting of the second alarm is deactivated. It
can be set as low alarm to send warning when charcoal is low.
AH1 and AH2 are the temperature to turn buzzer on; AL1 and AL2 are the temperature to turn buzzer off. When AH1(2) >
AL1(2), the alarm is set for absolute high alarm, When AH1(2) < AL1(2), the alarm is set for absolute low alarm, When
AH1(2) = AL1(2), the alarm is deactivated.
For example, if AH1 = 250, AL1 = 249, when the temperature goes up to 250° F, the buzzer will be on; when the
temperature drops down to 249° F, the buzzer will be off. If AH2 = 180, AL2 = 185, when the temperature drops down to
180° F, the buzzer will be on; when the temperature goes up to 185° F, the buzzer will be off.
User can press the shift key (>) to temporarily silence the buzzer sound alarm. The alarm will buzz again if the alarm set
temperature is reached again. To permanently deactivate the alarm, set AH1 = AL1 or AH2 = AL2. Please see flow chart
below on how to set the value.
Figure 2. Flow charge of how to set the target temperature (SV) and alarms.
(End)
No part of this manual shall be copied, reproduced, or transmitted in any way without the prior, written consent of Auber Instruments. Auber
Instruments retains the exclusive rights to all information included in this document.
Parameter Display
Operation Mode
Enter Code
SET
SET
xxxx
0001
SET
Auber Instruments Inc.
5755 North Point Parkway, Suite 99,
Alpharetta, GA 30022
www.auberins.com
Tel: 770-569-8420
Copyright 2007-2017, Auber Instruments All Rights Reserved.
Target Temp Selection
SET
0200
su
Buzzer On Temp
SET
0250
ah1
Buzzer Off Temp
SET
0249
al1
Buzzer On Temp
SET
0250
ah2
Buzzer Off Temp
SET
0250
al2
end
www.auberins.com
SET
SET
SET
SET
SET