Carbon brush replacement
Warning !!!
During cleaning and service the hand dryer
must always be disconnected from the
power supply.
1.Disconnect power supply.
2.Disassemble cover by removing the two
cover screws at the bottom of the housing.
Use the special Allen key which was
originally supplied with the hand dryer.
3. Disassemble angle bracket.
DAN DRYER A/S • Tåsingevej 2 • DK-8940 Randers SV • Tel: +45 86 41 57 11 • Email: [email protected]
Document
244 DAN DRYER Turbo (with nozzle)
Maintenance and service manual
Lang.
4. Loosen the 4 screws
on the fan housing and
disassemble fan
housing lid.
5. Gently lift up the motor.
Be careful not to damage
motor wiring.
6. Loosen carbon brush wiring.
7. Loosen the 2 x 2 screws,
allowing for the worn
brushes to be disassembled
from the motor.
8. Assemble new carbon
brushes and reassemble
screws and wires.
9. Reassemble all components
and test run hand dryer.