3
Mounting the kit
3.1 Mounting and connecting the power supply unit
Ausgabe/Edition:
Änderungsindex
03.2011
Rev. index: 00.0
Anbauanleitung für Barcodeleser
Teilesatz 0911 597554
Fitting Instructions Barcode Reader
Kit 0911 597554
Caution: Risk of injury!
Turn the main switch off!
Mount the kit only with the sewing unit switched off!
1
Remove the left cover cap 1.
Mount the power supply unit 4 with the spacer sleeves 3 and
the cylinder screws M4 x 25.
Connect the cable 5 (22 cm of 9870 911016) with the 3 pin plug
connection of the power supply unit 4.
Connect cable 5 to the 10-pole flat plug of the PCB 2:
white to 8 (+24V-1)
green to 10 (GND)
For the time being brown to 10 (GND) = Power supply
permanently active
From year of construction 2011:
Brown to 9 (Y9) = Power supply unit can be switched on with
output 21 on the operating panel.
5
Printed in Germany
Teile-Nr./ Part-No.:
0791 911702
4
3
2
Blatt:
von
Sheet: 10 from 16