Duerkopp Adler 0791 911702 Montaj Talimatları Kılavuzu - Sayfa 10

Barkod okuyucu Duerkopp Adler 0791 911702 için çevrimiçi göz atın veya pdf Montaj Talimatları Kılavuzu indirin. Duerkopp Adler 0791 911702 16 sayfaları. Barcode reader

Duerkopp Adler 0791 911702 Montaj Talimatları Kılavuzu
3
Mounting the kit
3.1 Mounting and connecting the power supply unit
Ausgabe/Edition:
Änderungsindex
03.2011
Rev. index: 00.0
Anbauanleitung für Barcodeleser
Teilesatz 0911 597554
Fitting Instructions Barcode Reader
Kit 0911 597554
Caution: Risk of injury!
Turn the main switch off!
Mount the kit only with the sewing unit switched off!
1
Remove the left cover cap 1.
Mount the power supply unit 4 with the spacer sleeves 3 and
the cylinder screws M4 x 25.
Connect the cable 5 (22 cm of 9870 911016) with the 3 pin plug
connection of the power supply unit 4.
Connect cable 5 to the 10-pole flat plug of the PCB 2:
white to 8 (+24V-1)
green to 10 (GND)
For the time being brown to 10 (GND) = Power supply
permanently active
From year of construction 2011:
Brown to 9 (Y9) = Power supply unit can be switched on with
output 21 on the operating panel.
5
Printed in Germany
Teile-Nr./ Part-No.:
0791 911702
4
3
2
Blatt:
von
Sheet: 10 from 16