B. Sanitation:
1. Flush, drain and sanitize system in
ac cor dance to owner's spec i fi ca tions.
Owner's cleaning solution must be com pat i ble with
regulator's trim materials.
NOTE: CIP is limited to 50 psig (3.45 Barg)
maximum cleaning solution pres sure at 300°F
(149°C).
SIP is recommended to 20 psig (1.38 Barg)
sat u rat ed steam pressure; can withstand 30
psig (2.07 Barg), but may reduce elastomer
life expectancy.
VIII.
ORDERING INFORMATION
NEW REPLACEMENT UNIT vs PARTS "KIT" FOR FIELD REPAIR
To obtain a quotation or place an order, please retrieve the Serial Number and Product Code that was stamped
on the metal name plate and attached to the unit. This information can also be found on the Bill of Material
("BOM"), a parts list that was provided when unit was originally shipped. (Serial Number typically 6 digits).
Product Code typical format as follows: (last digit is alpha character that refl ects revision level for the product).

NEW REPLACEMENT UNIT:

Contact your local Cashco, Inc., Sales Rep re sen-
ta tive with the Serial Number and Product code.
With this information they can provide a quotation
for a new unit including a complete description,
price and availability.
Do not attempt to alter the original construction
of any unit without assistance and approval from
the factory. All purposed changes will require a
new name plate with appropriate ratings and new
product code to accommodate the recommended
part(s) changes.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be
construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. We reserve the right to
modify or improve the designs or specifi cations of such product at any time without notice.
Cashco, Inc. does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any
Cashco, Inc. product remains solely with the purchaser.
IOM-C-PRV
CAUTION
CAUTION
C. Post-Sanitation:
1. Prior to system start-up, remove the lock-
open pin (10) from the adjusting screw (5)
and insert it into the pin retainer hole. Unit
is again operative at the setpoint established
prior to cleaning.
Figure 2: Spring Chamber in Lock-Open Position

SECTION VIII

7
PARTS "KIT" for FIELD REPAIR:
Contact your local Cashco, Inc., Sales Rep re sen-
ta tive with the Serial Number and Product code.
Identify the parts and the quantity required to repair
the unit from the "BOM" sheet that was provided
when unit was originally shipped.
NOTE: Those part numbers that have a quantity indicated
under "Spare Parts" in column "A" refl ect minimum
parts required for inspection and rebuild, - "Soft
Goods Kit". Those in column "B" include minimum
trim replacement parts needed plus those "Soft
Goods" parts from column "A".
If the "BOM" is not available, refer to the cross-
sectional drawings included in this manual for part
identifi cation and selection.
A Local Sales Representative will provide quotation
for appropriate Kit Number, Price and Availability.