1.STOP!Readthe safetyinformationabovein this manual.
2. Set the thermostatto the lowestsetting.
3. Turnoff all electricpowerto the appliance.
4. This applianceis equippedwith an ignitiondevicewhich auto-
maticallylightsthe burner.DO NOTTRYTO LIGHTTHE BURNER
BY HAND.
5. Removethe frontjacket panel.
6. Turnthe gas controlvalveclockwise
f_
to "OFF". The handle of
the valve should be perpendicular
to the pipe in the "OFF" position.
Control 'Valve "ON"
Control 'Valve "OFF"
7. Wait five (5) minutes
to clear out any gas. Then
smell for gas,
including
near the floor. If you smell gas, STOP!
Follow "B" in the
safety information
above
in this manual.
If you don't smell gas, go
to the next step.
8. Turn the gas control valve counterclockwise
_
to the "ON" posi-
tion. The handle of the valve should
be parallel
to the pipe in the
"ON" position.
9. Replace the front jacket
panel.
10. Set the thermostat
to the desired
setting.
11. Turn on all electric
power to the appliance.