12. If the appliancewill not operate,follow the instructionsunder
"ToTurnOffGasToTheAppliance"andcallyourservicetechnician
or gas supplier.
1.Turn off all electricpowerto the applianceif serviceis to be per°
formed.
2. Set the thermostatto the lowestsetting.
3. Removethe frontjacket panel.
4. Turnthe gas controlvalveclockwise
f_
to "OFF". The handle of
the valve should be perpendicular
to the pipe in the "OFF" position.
5. Replace the front jacket
panel.
THRDTTLE
INLET
PRESSURE_
TAP
INLET
IvlE]LEX
PIN
HEADER
VALVE
The Blocked
Flue/Vent
Safety
Shutoff
shuts off main burner gas in
the event that the flow of combustion
products
through
the flue ways
is reduced.
In the event of blocked flue ways, enough air will not be
available
to support
combustion,
and boiler control will lockout
due
to loss of proper air flow.If the boiler can not be restored
to normal
operating
condition
by resetting
the control,
contact
a qualified
sero
vice agency to check the flue ways and vent pipe for blockage.