8.2 Filter Maintenance

Visually check your filters every 10 hours and when you remove your pre-filters for cleaning. Check for accumulated material in
the filter element. If you suspect they may be dirty, or if you can see material building up, don't take a chance, remove the
filter and hold it up to the light.
To remove your filters, remove two dome nuts as shown in picture 1and pull filter plate off as shown in picture 2. Filter plate
can hang up on the threads so make sure you pull it off straight. Remove filter as shown in picture 3. If filter is stuck to the side
of the case, gently tap them with your hand.
To check your filters, hold them up to a light, similar to your car air intake filter. If you cannot see light through more than
50% of the filter, replace filter element.
NOTICE
Filter element may be damaged if more than 50 PSI of air pressure is used to blow out filter
element.
If they appear to be dirty, you can tap them gently on a flat surface to remove any debris. If you have compressed air
available, you can also blow them off with air. If you use compressed air to clean your filters, make sure you blow the air
from the inside out and never use more than 50 PSI or this will damage the filter element.
To reinstall the filters, reverse the instructions above. Make sure that you line the filter up with the filter plate first, this will
help to keep it straight when replacing the dome nuts.