INTERNAL RADIO
Memorising the transmitter code.
The control panel must be in a stable situation, door closed or door open, before memorising transmitter
codes.
a) Manual memorisation.
Memorise the code by pressing the programming button PROG TRANSMITTER (Fig.2) for 1.5 seconds.
The red indicator LED will light and there is an audible indication in the form of a beep. Release the button
and the LED will remain lit, indicating that the unit is ready to memorise a transmitter code.
Any code received after this time will be memorised. To do this, press the transmitter buttons for whichever
function you wish to be activated by the control system.
Memorisation is confirmed by the LED flashing and a beep.
The unit automatically exits memorisation mode 10 seconds after the last reception of a code. This is
indicated by the indicator LED going out and two short beeps.
b) Memorisation by radio using another transmitter.
To use this system, switch selector I6 to the ON position and have previously memorised at least one code
using system a).
Press the special function of one of the previously memorised transmitters, so that the unit enters the code
memorisation sequence with the indicator LED lit and a long beep.
This status enables any code received with the same function memorised for the transmitter using the special
function to be memorised. Press the same function on the transmitters as previously memorised by the
transmitter used for this system.
Memorise any other function by using system a).
Memorisation is confirmed by the indicator LED flashing and a beep.
The unit automatically exits memorisation mode 10 seconds after the last reception of a code. This is
indicated by the indicator LED going out. Exit memorisation mode manually by pressing the special
function of any of the transmitters memorised.
Deleting all the codes.
Delete all the codes by resetting the memory.
Press the PROG TRANSMITTER button for a total of 4 seconds and the red LED will flash and beep
rapidly indicating that all previously memorised codes have been deleted. The unit will remain in the code
memorisation sequence waiting to memorise new codes.
Out of memory indicator.
In the event of using all the memory available, i.e., having memorised 255 different codes, any attempt to
memorise new codes will result in a series of flashes of the red indicator LED and a 10 second beep.
ENG
ESP
PROGRAMMING THE AUTOMATIC DOOR OPENING AND CLOSING DISTANCE.
ATTENTION:
For the installation to work correctly, stoppers are needed on the bottom strip of the roller door (refer to
the drawings in the installation and adjustment instructions enclosed with the motor). The stoppers limit
how far the door opens, and how far the door closes is limited by prior programming.
The door travel distance must be programmed for the door to make a gentle stop on reaching the desired
position. This procedure also programs the automatic door closing time.
Press the programming button PROG for 1.5 seconds. The red indicator LED 'C' will flash indicating that
the unit is in programming mode.
To program the travel distance, the door must be completely closed. If the door is not fully closed, enter
programming mode and close the door using the adjustment buttons (A and B).
OPEN and CLOSE on the circuit board (A and B) (In programming mode these buttons act as human
present buttons and are used to close the door)
It is now possible to program the travel distance. First activate the alternative button to open the door as far
as the door open stopper.
Programming the travel distance
1 - Begin with the door in the closed position. Activate travel distance programming mode as
indicated above, the red LED 'C' will flash.
2 - If the door is not closed, close it using the Open and Close buttons on the circuit board which
in this case act as human present buttons (A and B).
3 - Begin the opening movement by pressing the alternative button "P.ALT" or the remote
control unit.
The movement will be stopped by the door open stoppers and the opening distance will be
memorised.
4 - With the door open, the time until automatic closure will be memorised.
5 - Begin the closing movement by pressing the alternative button "P.ALT" or the remote control
unit. The unit will automatically exit programming mode.
The maximum time for memorisation is 2 min. after which, the movement will stop and this limit will be
memorised.
If programming mode is activated, but no action is taken within 1 minute, the unit exits programming
mode.
When programming the motor it operates at slow speed.
FIRST MOVEMENT
When the programmed control is turned on, the first movement on pressing the alternative button or
a remote control unit is to open. The door moves at slow speed until reaching the door open stoppers.