– Confirm Ownership of the device: Enter the Windows username and password that is
associated with the login credentials of the computer the device is plugged into.
– Custom Device Information: Required information about you or your device. The
required fields will vary.
– Unique User Token: This token is directly associated with the end user's account and
will be provided by the System Administrator.
– Administrator Registration Approval: The System Administrator may require their ap-
proval to proceed with device registration.
2. Enter they Sentry K300 password into the client. This is the same password used to unlock the
device and any letters should be entered as capitals.
3. If the Sentry K300 doesn't currently have a file system, you will be prompted to choose one for
the Secure Volume (see
4. The device will now finalize the setup process and be ready for use. Access the Encrypted
Storage by clicking the Folder Icon in the top menu. The settings of the device can be
accessed and altered by clicking the Gear Icon. See the
information.

SafeConsole Mode

Once the Sentry K300 is registered to SafeConsole, the Secure Volume can be accessed by following
the steps below:
1. Enter the password into the K300.
2. Select Connect or Read Only Mode using the K300 keypad and physically connect it to your
workstation.
3. Select the option Unlocker.exe inside of the Unlocker partition that can be found in File
Explorer.
4. Click the Unlock button shown on the DataLocker Control Panel.
5. The Secure Volume will be mounted to a separate drive letter on your workstation. The Secure
Volume can also be accessed by clicking the Folder Icon in the DataLocker Control Panel.
© 2019 DataLocker Inc. All rights reserved.
Formatting The Sentry
Sentry K300 Managed User Guide
K300) and click Continue.
DataLocker Control Panel
for more
9