READING CONDITIONS

ANSI Grade B minimum
600 scans/sec per leg
The following tables describe the requirements for standard applications.
Conveyor Speed (m/s)
2/5 Inteleaved
Code Resolution (mm)
Conveyor Speed (m/s)
Code 39
Code Resolution (mm)
Conveyor Speed (m/s)
Code 128 – GS1-128
Code Resolution (mm)
Conveyor Speed (m/s)
Codabar
Code Resolution (mm)
Conveyor Speed (m/s)
EAN 8-13, UPC-A
Code Resolution (mm)
Minimum Code Height for Omnidirectional Reading (mm)
0.5
0.38
14
0.50
18
0.60
21
1.00
34
Minimum Code Height for Omnidirectional Reading (mm)
0.5
0.38
12
0.50
15
0.60
18
1.00
28
Minimum Code Height for Omnidirectional Reading (mm)
0.5
0.38
10
0.50
12
0.60
14
1.00
22
Minimum Code Height for Omnidirectional Reading (mm)
0.5
0.38
16
0.50
20
0.60
23
1.00
36
Minimum Code Height for Omnidirectional Reading (mm)
0.5
0.38
11
0.50
13
0.60
15
1.00
24
1
1.5
16
18
19
21
22
24
35
36
Table 1
1
1.5
13
15
16
17
19
20
29
30
Table 2
1
1.5
12
14
13
16
15
17
23
24
Table 3
1
1.5
18
20
22
24
25
27
38
40
Table 4
1
1.5
12
13
14
15
16
17
25
26
Table 5
DX6400 QUICK GUIDE
2
2.5
20
22
23
25
26
28
37
39
2
2.5
17
19
19
21
21
23
31
32
2
2.5
16
18
18
20
19
21
26
28
2
2.5
22
24
26
28
29
31
42
44
2
2.5
15
17
16
18
18
19
27
28
3
24
27
30
41
3
21
24
26
34
3
20
22
24
30
3
26
30
34
47
3
19
20
22
29
13