Datalogic DX6400 빠른 참조 매뉴얼 - 페이지 13
{카테고리_이름} Datalogic DX6400에 대한 빠른 참조 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Datalogic DX6400 17 페이지.
READING CONDITIONS
ANSI Grade B minimum
600 scans/sec per leg
The following tables describe the requirements for standard applications.
Conveyor Speed (m/s)
2/5 Inteleaved
Code Resolution (mm)
Conveyor Speed (m/s)
Code 39
Code Resolution (mm)
Conveyor Speed (m/s)
Code 128 – GS1-128
Code Resolution (mm)
Conveyor Speed (m/s)
Codabar
Code Resolution (mm)
Conveyor Speed (m/s)
EAN 8-13, UPC-A
Code Resolution (mm)
Minimum Code Height for Omnidirectional Reading (mm)
0.5
0.38
14
0.50
18
0.60
21
1.00
34
Minimum Code Height for Omnidirectional Reading (mm)
0.5
0.38
12
0.50
15
0.60
18
1.00
28
Minimum Code Height for Omnidirectional Reading (mm)
0.5
0.38
10
0.50
12
0.60
14
1.00
22
Minimum Code Height for Omnidirectional Reading (mm)
0.5
0.38
16
0.50
20
0.60
23
1.00
36
Minimum Code Height for Omnidirectional Reading (mm)
0.5
0.38
11
0.50
13
0.60
15
1.00
24
1
1.5
16
18
19
21
22
24
35
36
Table 1
1
1.5
13
15
16
17
19
20
29
30
Table 2
1
1.5
12
14
13
16
15
17
23
24
Table 3
1
1.5
18
20
22
24
25
27
38
40
Table 4
1
1.5
12
13
14
15
16
17
25
26
Table 5
DX6400 QUICK GUIDE
2
2.5
20
22
23
25
26
28
37
39
2
2.5
17
19
19
21
21
23
31
32
2
2.5
16
18
18
20
19
21
26
28
2
2.5
22
24
26
28
29
31
42
44
2
2.5
15
17
16
18
18
19
27
28
3
24
27
30
41
3
21
24
26
34
3
20
22
24
30
3
26
30
34
47
3
19
20
22
29
13