Dust Free MicroPure 9" with MX4 Panduan Pemilik - Halaman 9
Jelajahi secara online atau unduh pdf Panduan Pemilik untuk Pembersih Udara Dust Free MicroPure 9" with MX4. Dust Free MicroPure 9" with MX4 12 halaman. Total home active air purifier
FIBERGLASS DUCTWORK INSTALLATION
5
5. Insert (4) 2" Threaded bolts into screw holes
at corners of mounting plate. Attach (4) toggle
bolt anchors to ends of threaded bolts.
7
7. Insert (4) toggle bolts into 3/8" holes in duct.
Be sure toggle anchors open after inserting.
9
9. Insert unit into opening. Be sure the air will
pass though the MX4™ core.
11
11. Plug unit into working power receptacle or
hardwire to proper power.
Hard wiring unit into HVAC system
should be done by a licensed
HVAC installer or electrical
contractor.
(CONTINUED)
6
Stud
6. Remove backing from mounting plate
adhesive gasket.
8
8. Center large opening in mounting plate over
3.5" opening in duct and press plate to duct.
The adhesive gasket will hold the mounting
plate into place.
Tighten toggle bolts - DO NOT OVERTIGHTEN.
10
10. Secure the unit to the mounting plate with
(4) hex nuts.
9