FIBERGLASS DUCTWORK INSTALLATION
5
5. Insert (4) 2" Threaded bolts into screw holes
at corners of mounting plate. Attach (4) toggle
bolt anchors to ends of threaded bolts.
7
7. Insert (4) toggle bolts into 3/8" holes in duct.
Be sure toggle anchors open after inserting.
9
9. Insert unit into opening. Be sure the air will
pass though the MX4™ core.
11
11. Plug unit into working power receptacle or
hardwire to proper power.
Hard wiring unit into HVAC system
should be done by a licensed
HVAC installer or electrical
contractor.
(CONTINUED)
6
Stud
6. Remove backing from mounting plate
adhesive gasket.
8
8. Center large opening in mounting plate over
3.5" opening in duct and press plate to duct.
The adhesive gasket will hold the mounting
plate into place.
Tighten toggle bolts - DO NOT OVERTIGHTEN.
10
10. Secure the unit to the mounting plate with
(4) hex nuts.