A complete NETCFG.INI example for Master and Slave units:
Master unit (VS-700)
PS/2
RS-232
VGA
LAN
Line in
USB
Line out
SPDIF
Mic
DC 19V
USB
DVI
eSATA
USB
HDMI
Power Supply
NETCFG.INI (for Master unit)
IP_OVERWRITE=1
IP=10.1.0.70
NETMASK=255.255.255.0
GATEWAY=10.1.0.1
DNS1=0.0.0.0
DNS2=0.0.0.0
NETSYNC_MASTER_MODE=1
NETSYNC_NUM_SLAVE=4
3.3 Disable the DVSYNC.INI
All VS-700 are shipped with "DVSYNC.INI" disable setting. If this DVSYNC.INI was
enabled, the video sync among master and slaves might not successful.
In case you find the slaves units cannot video sync with each others, please try to
disable the dvsync.ini through the following procedures.
1. Create a dummy DVSYNC.INI (i.e. a blank file) and place it in the "media" folder
on the USB flash drive.
2. Update the dummy DVSYNC.INI on to the Master unit (VS-700) and all Slave unit
(VS-700) through USB update. (see VS-700 user guide)
© DV Signage 2012
Network switch
100M
LNK / ACT
1
1
2
2
3
3
4
4
5
5
6
6
Power Supply
RJ-45 (Straight cable)
Slave unit (VS-700)
PS/2
RS-232
VGA
LAN
7
7
8
8
USB
SPDIF
USB
HDMI
DVI
eSATA
USB
Connect to Monitor
RJ-45 (Straight cable)
Slave unit (VS-700)
PS/2
RS-232
VGA
LAN
USB
SPDIF
DVI
USB
HDMI
eSATA
USB
Connect to Monitor
RJ-45 (Straight cable)
Slave unit (VS-700)
PS/2
RS-232
VGA
LAN
USB
SPDIF
USB
DVI
USB
HDMI
eSATA
Connect to Monitor
RJ-45 (Straight cable)
Slave unit (VS-700)
PS/2
RS-232
VGA
LAN
USB
SPDIF
USB
DVI
USB
HDMI
eSATA
Connect to Monitor
RJ-45 (Straight cable)
NETCFG.INI (for Slave unit)
IP=10.1.0.71
NETMASK=255.255.255.0
GATEWAY=10.1.0.1
Line in
DNS1=0.0.0.0
Line out
DNS2=0.0.0.0
Mic
NETSYNC_SLAVE_MODE=1
DC 19V
NETSYNC_MASTER_ADDR=10.1.0.70
Power Supply
NETCFG.INI (for Slave unit)
IP_OVERWRITE=1
IP=10.1.0.72
NETMASK=255.255.255.0
Line in
GATEWAY=10.1.0.1
Line out
DNS1=0.0.0.0
Mic
DC 19V
DNS2=0.0.0.0
NETSYNC_SLAVE_MODE=1
NETSYNC_MASTER_ADDR=10.1.0.70
Power Supply
NETCFG.INI (for Slave unit)
IP_OVERWRITE=1
IP=10.1.0.73
NETMASK=255.255.255.0
Line in
GATEWAY=10.1.0.1
Line out
DNS1=0.0.0.0
Mic
DNS2=0.0.0.0
DC 19V
NETSYNC_SLAVE_MODE=1
NETSYNC_MASTER_ADDR=10.1.0.70
Power Supply
NETCFG.INI (for Slave unit)
IP_OVERWRITE=1
IP=10.1.0.74
NETMASK=255.255.255.0
Line in
GATEWAY=10.1.0.1
Line out
DNS1=0.0.0.0
Mic
DNS2=0.0.0.0
DC 19V
NETSYNC_SLAVE_MODE=1
NETSYNC_MASTER_ADDR=10.1.0.70
Power Supply
Page 8 of 14