To use timer mode, you can either press the SHOT button on the front panel of the
SD-100 unit or press down on the foot pedal.
Cycle Mode
Cycle mode allows the user to create a repeating cycle of dispensing. This is programed
by setting a wait time between dispensing. This mode is reliant on the previous setting
that was made in timer mode to determine the length of dispensing during the cycle.
For example: If you would like to dispense for 1 second, then wait for 5 seconds, and
cycle these times over again, you would need to have already set your timer mode for
1 second (see previous page for these instructions). To set the 5 second wait time in
your cycle, follow the directions below.
1.
Press the MODE button until the cycle mode is selected.
2.
Press the SET button. The first digit on the right side of the digital display will start
blinking.
3.
Press the ◄ button two times. The third digit from the right should be blinking.
4.
Press the ▲ button five times. The display should now show a 5 second wait time.
(To adjust the decimal refer to page 15)
5.
Press Exit/Mode to save as current setting.
To use the cycle mode, press the SHOT button on the SD-100 to activate the cycle. To
deactivate the cycle, press the EXIT button.
Saving Dispense to Memory
The SD-100 has the storage capacity for up to 9 programs that can be saved to its
memory for future recall. The memory will always save your current settings for the
particular mode you are in.
For example: If you want to save your current timer mode setting to Program 9, you will
first need to select timer mode then proceed with saving. You can also save your cycle
mode settings to Program 9 by following the same procedure.
To save your current settings to memory address 9, follow the instructions below.
1.
While in timer or cycle mode, change to the mode you would like to save then
press and hold the MEM (Memory) key for 2 seconds until the unit beeps.
SD-100 Digital Syringe Dispenser User Guide