GREAT ARBOR GAC-300 Panduan Pengguna - Halaman 4
Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Router Jaringan GREAT ARBOR GAC-300. GREAT ARBOR GAC-300 4 halaman. Wifi dial up router
Select
t he
i ncoming
p rotocols
( TCP,
U DP,
T CP
a nd
U DP
o r
c ustom
I P
p rotocol
n ame),
t he
p orts,
a nd
t he
I P
a ddress
o f
t he
s erver
o n
t he
L AN
( Internal
I P
a ddress)
t hat
t he
t raffic
i s
t o
be
r edirected
t o.
F or
e xample,
f or
a
w eb
s erver
o n
t he
L AN,
t he
p rotocol
i s
T CP
a nd
w ith
p ort
b eing
8 0.
P ress
A dd
a nd
t hen
S ave
&
A pply
t o
s ave
t he
c hanges.
Compatible ISPs
Most
d ialup
I SPs
a re
c ompatible
w ith
L inux
a nd
t he
G AC-‐ 3 00
e ven
t hough
t hey
m ay
s tate
t hat
t hey
d o
n ot
o ffer
c ustomer
s upport
f or
L inux.
E xceptions
a re
N etZero/Juno
a nd
A ol
who
r ely
o n
s pecial
d ialer
s oftware
a nd
a re
i ncompatible.
I n
g eneral,
t he
h ighest
s peed
w ill
b e
a chieved
w ith
I SPs
w ho
s upport
V .92
a ccess.
T he
I SPs
w ho
a re
k nown
t o
w ork
a re:
Copper.net,
T oast.net,
S ocalfree.net,
C enturyTel.net,
S ympatico.ca,
D elmarva
O nline,
A T&T,
M SN,
T elus(Canada),
a nd
P eoplePC.
Troubleshooting
I can't get connected to the Router
First
m ake
s ure
t hat
t he
W iFi
c onnection
t o
t he
r outer
a t
I P
a ddress
1 92.168.1.1
i s
e stablished.
T o
v erify,
t ype
t he
c ommand
p ing
1 92.168.1.1
o n
y our
P C.
L ack
o f
a
r esponse
i ndicates
that
t he
W iFi
c onnection
i s
n ot
m ade
a nd
y ou
m ay
h ave
t o
r escan
f or
n etworks
a nd
r econnect
t o
O penWrt.
I f
y ou
c an't
m ake
t he
W iFi
c onnection,
c onnect
y our
P C
v ia
t he
L AN
connection
t o
t he
r outer
a nd
t ry
t he
p ing
t est
a gain.
The Internet LED (Globe) does not start flashing 2-3 minutes after power up
This
i ndicates
t here
i s
a
p roblem
i n
c onnecting
t o
y our
I SP.
E nsure
t hat
t he
b lack
m odem
i s
c onnected
t o
t he
U SB
p ort
o f
t he
r outer
a nd
t hat
t he
m odem
i s
c onnected
t o
t he
p hone
line.
M ake
s ure
t hat
n o
o ne
e lse
i s
u sing
t he
p hone
w hen
y ou
d ial
u p.
A lso
c onfigure
s ome
o ther
I SP
a ccess
p hone
n umber
i n
c ase
t he
o riginal
n umber
i s
b usy.
In
m any
c ases,
y ou
w ill
h ave
t o
l ook
a t
t he
D ialup
S tatus
S creen
t o
d iagnose
f urther.
C lick
S tatus
a nd
t hen
c lick
t he
D ialup
o ption
o n
t he
u pper
r ight.
T he
p age
d isplays
t he
s tatus
o f
the
c onnection
s uch
a s
" No
D ialtone",
" Waiting
t o
C onnect",
o r
" Modem
c onnected
t o
f ar
e nd
-‐
D oing
P assword
A uthentication".
I f
P PP
a uthentication
f ails,
c heck
t he
I SP
a ccount
user
n ame
a nd
p assword.
F or
f urther
a ssistance,
s elect
t he
l ines
o n
t he
w eb
p age
a nd
C opy/Paste
i t
i nto
a n
E mail
t o:
s [email protected]
u sing
n ormal
P C
c ommands
( On
Windows,
y ou
c an
u se
C ntrl-‐ A
f or
S elect
A ll,
C ntrl-‐ C
f or
C opy,
a nd
C ntrl-‐ V
f or
P aste).
A lso
s end
t he
r outer
c onfiguration
a s
a n
a ttachment
t o
t he
s upport
e mail.
T he
r outer
c onfiguration
is
o btained
b y
c licking
S ystem,
a nd
t hen
c licking
B ackup/Flash
F irmware.
S elect
G enerate
a rchive
t o
c reate
a
f ile
w hich
c an
b e
a ttached
t o
t he
e mail.
I made some changes to the router and it doesn't work any more
Use
t he
R eset
t o
d efaults
o ption
i n
t he
B ackup/Flash
F irmware
p age
t o
g o
b ack
t o
t he
f actory
c onfiguration.
A nother
w ay
t o
r eset
t o
d efaults
i s
t o
p ress
t he
r eset
b utton
f or
8
s econds.
All
t he
L EDs
w ill
g o
o ff
a nd
t hen
t he
S YS
L ED
( next
t o
t he
P WR
L ED)
w ill
s tart
b linking.
T he
r estored
f actory
c onfiguration
w ill
c ome
b ack
u p
i n
2 -‐ 3
m inutes
a nd
t he
S YS
L ED
w ill
b e
s olid
green.
A ll
y our
c hanges
w ill
b e
w iped
o ut
s o
c onfigure
t he
d ial
u p
a ccount
a gain
a s
d iscussed
e arlier.
Speeds are very low
Dialup
s peeds
d epend
o n
t he
c ondition
o f
y our
p hone
l ine
a nd
t he
m odem
c onfiguration
o f
y our
I SP.
I t
i s
n ormal
t o
g et
d ownload
s peeds
o f
4 0
k bps
a nd
u pload
s peeds
o f
3 0
k bps.
Can't receive phone calls
Once
y ou
a re
c onnected
t o
t he
I nternet,
y ou
w ill
n ot
b e
a ble
t o
r eceive
a ny
c alls
o n
y our
p hone
l ine.
T o
p revent
t his,
m ake
s ure
t o
d isconnect
a fter
t he
d ial
u p
s ession
o r
p ower
o ff
the
r outer.
Y ou
c an
a lso
s elect
t he
o ption
t o
d rop
t he
d ial
u p
c onnection
i n
c ase
o f
a n
i ncoming
c all
( see
F igure
4 ).
Symptom
Factory configured ISP is not accessible even
after waiting a few minutes after power up
Your configured dial up access number does
not work
Cannot connect to router
Warranty
Great
A rbor
C ommunications
w arrants
t his
p roduct
a gainst
d efect
i n
m aterials
a nd
w orkmanship
f or
1
y ear
a fter
p urchase
o f
t he
u nit.
P roducts
r equiring
w arranty
s ervice
s hould
b e
returned
t o
G reat
A rbor
i n
o riginal
p ackaging
a fter
r eceipt
o f
a
R MA
N umber.
A ny
p roduct
r eplaced
b y
G reat
A rbor
s hall
r etain
a
w arranty
f or
t he
r emaining
w arranty
p eriod.
Warranty Exceptions
•
Any defect caused by misuse, improper installation or maintenance that is not required as per the instructions;; Any unauthorized disassembly and repair;;
•
Any defect caused by improper use in the working conditions beyond the stated ones by the instruction (for example: use under abnormal temperatures that are too high, low, wet or
dry;; high sea-level;; unstable electric current and voltage and so on)
•
Any defect caused by personal disaster or improper maintenance, such as mechanical damage, serious oxidation and rusting, rat damage, permeating exertion and so on;;
•
Any defect caused by transportation or loading during return shipment;;
•
Any damage caused by natural disasters such as earthquake, fire, flood, lightning strike, or any other natural occurrence;;
•
Any other defects that are not caused by workmanship, technique, product quality and the like.
Notices:
•
Warranty service stated above is only valid for products sold in the continental USA and Canada.
•
As for any direct or indirect loss caused by abnormal use of the product, Great Arbor shall only be liable for the duties that are stipulated by relevant state law.
•
Great Arbor shall neither, on any account, respond to any loss or damages caused by intangible property such as applications or configurations, nor respond to any accusation put
forward by a third party.
•
Great Arbor reserves all rights including interpretation and modification to this warranty policy.
•
Great Arbor shall not be liable for long distance charges or incur any liability for inadvertent dial up due to malfunctioning of the unit or user
To
prevent
unintended
dial
up,
power
off
the
router
after
use.
Great
Arbor
Communications
disclaims
all
responsibility
for
inadvertent
dial
up
due
to
software/hardware
malfunction
o r
u ser
c onfiguration.
ã 2016 Great Arbor Communications
Troubleshooting Table
Next Steps
Make sure the phone cable is plugged in and Tone/Pulse Dial is set correctly and the line is not busy. After
unsuccessful call, copy System Log and router backup file into an email to support
Make sure that your ISP access phone number is correct (do you need to put in the area code ?) - try dialing the
number with a regular phone, and if you hear beeps and tones the number is correct. Check user name and
password for ISP account. Send System Log and router backup file to support.
Make sure your PC WiFi is enabled and you see the OpenWrt network.
www.greatarbor.com
4