Gaggenau GI 966 760 Manual - Halaman 11
Jelajahi secara online atau unduh pdf Manual untuk Mesin pencuci piring Gaggenau GI 966 760. Gaggenau GI 966 760 14 halaman.
ELECTRICAL SUPPLY CONNECTION
THESE INSTALLATION
INSTRUCTIONS ARE
INTENDED FOR USE BY
QUALIFIED INSTALLERS
Connecting Electrical Supply
Be sure to follow all local and natio-
nal electrical codes and ordinances.
• Install strain relief or conduit connector
into opening on J-box.
• Strip the insulated wires, being extremely
careful not to strip too much insulation.
• Insert and securely fasten into strain re-
lief, two-conductor supply cable with
ground.
• Twist wire connectors tightly onto the
wires, ensuring that no bare wiring is
exposed (from insulated wires).
• Press wires back into J-box
• Securely fasten the J-box cover or toe
panel (depending on model) with
screw(s) provided from accessories
package.
Grounding Instructions
This appliance must be connected to a
grounded metal permanent wiring system;
or an equipment grounding conductor
must be run with the circuit conductors
and connected to the equipment grounding
terminal or lead on the dishwasher. The
dishwasher must be properly grounded
before operating. Make sure that the
dishwasher is connected to a suitable
ground in compliance with the NATIONAL
ELECTRICAL CODE, in the United States,
or the CANADIAN ELECTRIC CODE C22.1-
latest edition, in Canada as well as any pro-
vincial/state or municipal or local codes that
apply.
ELECTRICAL SHOCK HAZARD
• DISCONNECT ELECTRICAL POWER
AT THE CIRCUIT BREAKER BOX OR
FUSE BOX BEFORE INSTALLING THE
DISHWASHER.
• ELECTRICALLY GROUND DISH-
WASHER.
• USE COPPER CONDUCTORS ONLY.
FAILURE TO FOLLOW THESE
INSTRUCTIONS COULD RESULT IN
SERIOUS INJURY OR DEATH.
Correct Connection in Junction Box
Figure 17
Incorrect Connection in Junction Box
Figure 18
www.gaggenau.com/us
WARNING
Black to Black
White to White
Green or Bare
to Green or Bare
U.L. listed
Conduit
Connector
or Strain
Relief
ENGLISH - 11