Fig. 21
Fig. 22
Fig. 23
16
– Secure the hood on the wall with the four screws b
(Fig. 21 and 22).
For exhaust air mode proceed as follows:
– Establish the pipe connection.
– Establish the electrical connection.
– Stainless steel chimney only (AD 010-012/022):
pull the protective film off the chimney's trims.
Note: avoid damaging the sensitive metal surfaces.
– Fit the top chimney duct unit into the base. Make
sure that the fastening holes on the side are at the
top.
– Put both chimney duct units onto the hood.
– Pull the top chimney duct unit up into its final
position and secure it with 2 screws on the ceiling
holder (Fig. 23).
Note: avoid scratches when pulling the elements
apart by placing the assembly template, for
example, over the edge of the bottom chimney
paneling to protect it.
– Insert the grease filters.