to the Output family. Thees outputs have dedicated DIP switches that identify the OUTPUT ID.
Maximum number of devices possible:
2. Connect Zone Inputs
The following diagrams illustrate the various possible zone connections to the main unit or to the 8 wired zone expander.
Notes:
For a zone with a tamper switch, you can use a double end-of-line resistor to save additional main panel connections.
It is recommended that you use an end-of-line resistor at the far end of each hardwired zone (16 x 2.2K resistors are supplied).
In the 2GIG Vario system, you have the ability to separately define the end-of-line resistance of the zones on the main unit and of the wired the wired zones for
each eight-unit expander block (Quick Keys ② ① ③ ). Selection is done by the software with the following available options:
6
Device
Wired/BUS expanders
BUS zones
WL zone expanders
BUS zone expanders
Output expanders
Keypads
1.5A or 4A power supplies
ID
EOL
0
Customized
1
2.2K
2.2K (Default)
2
4.7K
6.8K
3
6.8K
2.2K
4
10K
10K
5
3.74K
6.98K
6
2.7K
2.7K
7
4.7K
4.7K
8
3.3K
4.7K
9
1K
1K
10
3.3K
3.3K
11
5.6K
5.6K
12
2.2K
1.1K
13
2.2K
4.7K
Total
3
32
2
4
4
4
4
DEOL
Copyright © 2016 Nortek Security & Control LLC
2GIG Vario Quick Install Guide