2gig Technologies Vario Manual de instalação rápida - Página 6
Procurar online ou descarregar pdf Manual de instalação rápida para Sistema de segurança 2gig Technologies Vario. 2gig Technologies Vario 18 páginas. Voice module
Também para 2gig Technologies Vario: Manual de instruções de instalação (6 páginas), Manual rápido do utilizador (10 páginas)
to the Output family. Thees outputs have dedicated DIP switches that identify the OUTPUT ID.
Maximum number of devices possible:
2. Connect Zone Inputs
The following diagrams illustrate the various possible zone connections to the main unit or to the 8 wired zone expander.
Notes:
For a zone with a tamper switch, you can use a double end-of-line resistor to save additional main panel connections.
It is recommended that you use an end-of-line resistor at the far end of each hardwired zone (16 x 2.2K resistors are supplied).
In the 2GIG Vario system, you have the ability to separately define the end-of-line resistance of the zones on the main unit and of the wired the wired zones for
each eight-unit expander block (Quick Keys ② ① ③ ). Selection is done by the software with the following available options:
6
Device
Wired/BUS expanders
BUS zones
WL zone expanders
BUS zone expanders
Output expanders
Keypads
1.5A or 4A power supplies
ID
EOL
0
Customized
1
2.2K
2.2K (Default)
2
4.7K
6.8K
3
6.8K
2.2K
4
10K
10K
5
3.74K
6.98K
6
2.7K
2.7K
7
4.7K
4.7K
8
3.3K
4.7K
9
1K
1K
10
3.3K
3.3K
11
5.6K
5.6K
12
2.2K
1.1K
13
2.2K
4.7K
Total
3
32
2
4
4
4
4
DEOL
Copyright © 2016 Nortek Security & Control LLC
2GIG Vario Quick Install Guide