DYNACO SCA-80Q Manual - Halaman 8
Jelajahi secara online atau unduh pdf Manual untuk Penguat DYNACO SCA-80Q. DYNACO SCA-80Q 12 halaman. C9 replacement
Juga untuk DYNACO SCA-80Q: Panduan Perakitan (15 halaman)
c. Wire 3 – green wire from the left amplifier channel to the other end of the
positive harness. If this wire is too short to reach, extend it with a bit of the
supplied red wire, and use heat shrink tubing to cover the joint. See
Appendix 1 for details.
4. Reconnect the ground wire, Wire 4 in Figure 6.
5. Inspect your work carefully. Make sure that there is no possible way for wires
connected to the positive and negative terminals of the new C9 configuration to
come into contact.
Page 8 of 12