3.0 CALCULATED TIME SETUP
3.1 SETTING NUMBER OF MINUTES PER HOUR OF SUPPLIED AIR FLOW REQUIRED
Enter the minutes per hour that you require fresh air to be brought into the home. Factory
default is 20 minutes. Press MODE to advance to the next setting
3.2 SETTING OPTIONAL MIXING TIME
If the user needs more central fan time for whole house mixing than the amount that is
provided by ventilation time, the central fan can be configured to run an additional time
period to complete the mixing period. Factory default is 0 or OFF. The fresh air damper
will not be open during this extra time. Press MODE to advance to the next setting.
3.3 SETTING OPERATION HOURS
If the user does not want the ventilation system to run throughout the day you can set
ON time and OFF time. Factory default is NO. If you are not setting an ON and OFF time,
press MODE and continue to section 3.4.
N
If you want to set hours of operation press the UP arrow for yes [YS]. Press MODE to select
yes. The AirCycler® g1 will prompt you to enter the hour you would like the ventilation
to begin and the hour you want it to end followed by the current time.
Set the hour you want ventilation to START.
Press MODE to advance to the next setting.
Set the hour you want the ventilation to STOP.
Press MODE to advance to the next setting.
3.3.1 SETTING CURRENT TIME
Enter the current time.
Press MODE to save all settings. Setup is complete.
3.4 CALCULATED TIME SETUP IS COMPLETE
Setup is complete. The AirCycler® g1 will now return to normal operation.