Ordering Information
This is only for reference, the actual product does not support all combinations.
For selecting the specified model, follow the Autonics website.
MP
5
M
-
❶
❷
❶ Power supply
2: 24 VACᜠ 50 / 60 Hz, 24 - 48 VDCᜡ
4: 100 - 240 VACᜠ 50 / 60 Hz
Product Components
• Product (+ bracket)
Dimensions
• Unit: mm, For the detailed drawings, follow the Autonics website.
□72
■ Bracket
46
Connections
• HOLD / RESET terminal function is different depending on the operation mode.
(F1 to F10: HOLD, F11 to F14: RESET)
• SOURCE: 100 - 240 VACᜠ 50 / 60 Hz 9 VA
24 VACᜠ 50 / 60 Hz 6.5 VA, 24 - 48 VDCᜡ 5 W
■ Cautions during Wiring
• Unit: mm, Use terminals of size specified
below.
≥3.5
≤7.0
■ Relay single output
HOLD /
INA
INB
+12 V
0 V
RESET
HIGH
8
9
10
11
12
13
14
15
16
17
1
2
3
4
5
6
7
CONTACT OUT:
250 VACᜠ 3 A, 30 VDCᜡ 3 A
RESISTIVE LOAD
SOURCE
❷ Output
N:
Indicator
1: Relay single (high-limit) +
NPN open collector output
2: Relay double (high / low-limit) +
NPN open collector output
• Instruction manual
14.3
75
11.8
■ Panel cut-out
≥ 91
5
4
■ Indicator
HOLD /
INA
INB
+12V
0V
RESET
8
9
10
11
12
1
2
3
4
5
■ Relay double output
HOLD /
INA
INB
+12V
0V
HIGH LOW
RESET
8
9
10
11
12
H
L
1
2
3
4
5
CONTACT OUT:
250 VACᜠ 3 A, 30 VDCᜡ 3 A
RESISTIVE LOAD
Specifications
Series
Input signal
01)
Voltage input
No-voltage input
Display method
Character size
Prescale
Hysteresis
Display cycle
Display range
Contact control output Relay
Type
Capacity
Solid-state control output NPN open collector
Type
Capacity
Approval
Unit weigth (package) ≈ 168 g (≈ 243 g)
01) Standard duty ratio 1:1
02) Operation mode F7, F8: ≤ 1 kHz (pulse width: ≥ 500 ㎲)
03) The hysteresis setting range varies according to the decimal point setting position.
04) Only available operation mode F2, F14
Power supply
Power consumption
External power supply ≤ 12 VDCᜡ ±10 % 80 mA
Memory retention
Relay life cycle
Insulation resistance
Dielectric strength
Noise immunity
Vibration
Vibration
(malfunction)
Shock
Shock (malfunction)
Ambient temperature
Ambient humidity
Operation mode
F1
Frequency / revolutions / speed
F2
Passing speed
F3
Cycle
F4
Passing time
F5
Time interval
F6
Time differential
F7
Absolute ratio
F8
Density
F9
Length measurement 1
F10
Interval
F11
Accumulation
Addition / subtraction-
F12
individual input
Addition / subtraction-phase
F13
difference input
F14
Length measurement 2
13
14
Mode Setting
15
[MODE]
16
RUN
17
[MODE] 2 sec
01) Press [▲], [◀] key or [MODE] key for 1.5 sec after entering parameter: select parameter groups.
6
7
Parameter Setting
SOURCE
• Some parameters are activated / deactivated depending on the model or setting of
other parameters. Refer to the description of each parameter.
• The parameter and setting value are cross-displayed on the display part.
• If any key is not entered for 60 sec in each parameter, it returns to RUN mode.
13
14
• [MODE] key: Saves current setting value and moves to the next parameter.
[◀] key: Checks fixed value / Changes setting digits.
[▲], [◀] key: Changes setting values.
15
■ Parameter 0 group
16
17
Parameter
Max.
P0-1
monitoring
value
6
7
Min.
P0-2
monitoring
value
SOURCE
MP5M-□N
MP5M-□1
Solid state input 1: ≤ 50 kHz (pulse width: ≥ 10 ㎲)
Solid state input 2
: ≤ 5 kHz (pulse width: ≥ 100 ㎲)
02)
Contact input: ≤ 45 Hz (contact: ≥ 12 VDCᜡ 5 mA, pulse width: ≥ 11 ms)
Input impedance: 3.9 kΩ, [H]: 4.5 - 24 VDCᜡ, [L]: 0 - 1 VDCᜡ
Short-circuit impedance: ≤ 80 Ω, residual voltage: ≤ 1 VDCᜡ,
open-circuit impedance: ≥ 100 kΩ
7-segment LED (zero blanking method)
W 4 × H 8 mm
0.0001 × 10
to 9.9999 × 10
-9
9
-
0 to 9999
03)
OFF
, 0.05, 0.5, 1, 2, 4, 8 sec (same as update output cycle)
04)
-19999 to 99999
-
1c × 1
250 VACᜠ 3 A, 30 VDCᜡ
-
3 A resistive load
-
× 1
-
≤ 30 VDCᜡ 100 mA
ᜢ ᜧ ᜫ
≈ 181g (≈ 256g)
AC voltage
AC / DC voltage
100 - 240 VACᜠ ᜠ ± 10 %
24 VACᜠ ± 10 % 50 / 60 Hz,
50 / 60 Hz
24 - 48 VDCᜡ ± 10 %
≤ 9 VA
AC: ≤ 6.5 VA, DC: ≤ 5 W
Number of inputs: 100,000 operations (non-volatile semiconductor memory type)
Mechanical: ≥ 5,000,000 operations
Electrical: ≥ 100,000 operations (250 VACᜠ 3 A resistive load)
≥ 100 MΩ (500 VDCᜡ megger)
2,000 VACᜠ 60 Hz for 1 min
± 2 kV the square wave noise (pulse width: 1㎲) by the noise simulator
0.75 mm double amplitude at frequency of 10 to 55 Hz in each X, Y, Z
direction for 1 hour
0.5 mm double amplitude at frequency of 10 to 55 Hz in each X, Y, Z
direction for 10 min
300m / s² (≈ 30G) in each X, Y, Z direction for 3 times
100m / s² (≈ 30G) in each X, Y, Z direction for 3 times
-10 to 50 ℃, storage: -20 to 60 ℃ (no freezing or condensation)
35 to 85 %RH, storage: 35 to 85 %RH (no freezing or condensation)
Measurement range
0.0005 Hz to 50 kHz
0.01 to max. of each time range F.S. ± 0.01 % rdg ± 1-digit
0.0005 Hz to 50 kHz
0 to 99999
-19999 to 99999
0 to 99999
→
Parameter 0 group
[MODE]
→
Parameter group
[MODE] 3 sec
01)
Display
Default
Setting range
hPEK 99999
• Reset (PV): [◀] key for over 2 sec
lPEK `9999
MP5M-□2
1a × 2
250 VACᜠ 3 A, 30 VDCᜡ
3 A resistive load
× 2
≤ 30 VDCᜡ 100 mA
≈ 190 g ( ≈ 265 g)
Measurement accuracy
(23 ± 5 ℃)
F.S. ± 0.05 % rdg ± 1-digit
F.S. ± 0.05 % rdg ± 1-digit
-
→
RUN
→
Display
condition
P1-1 Input
operation
mode:
except F11,
F14