Autonics MP5M-N Series Manuale del prodotto - Pagina 2
Sfoglia online o scarica il pdf Manuale del prodotto per Strumenti di misura Autonics MP5M-N Series. Autonics MP5M-N Series 6. Thumbwheel switch multi pulse meters
Ordering Information
This is only for reference, the actual product does not support all combinations.
For selecting the specified model, follow the Autonics website.
MP
5
M
-
❶
❷
❶ Power supply
2: 24 VACᜠ 50 / 60 Hz, 24 - 48 VDCᜡ
4: 100 - 240 VACᜠ 50 / 60 Hz
Product Components
• Product (+ bracket)
Dimensions
• Unit: mm, For the detailed drawings, follow the Autonics website.
□72
■ Bracket
46
Connections
• HOLD / RESET terminal function is different depending on the operation mode.
(F1 to F10: HOLD, F11 to F14: RESET)
• SOURCE: 100 - 240 VACᜠ 50 / 60 Hz 9 VA
24 VACᜠ 50 / 60 Hz 6.5 VA, 24 - 48 VDCᜡ 5 W
■ Cautions during Wiring
• Unit: mm, Use terminals of size specified
below.
≥3.5
≤7.0
■ Relay single output
HOLD /
INA
INB
+12 V
0 V
RESET
HIGH
8
9
10
11
12
13
14
15
16
17
1
2
3
4
5
6
7
CONTACT OUT:
250 VACᜠ 3 A, 30 VDCᜡ 3 A
RESISTIVE LOAD
SOURCE
❷ Output
N:
Indicator
1: Relay single (high-limit) +
NPN open collector output
2: Relay double (high / low-limit) +
NPN open collector output
• Instruction manual
14.3
75
11.8
■ Panel cut-out
≥ 91
5
4
■ Indicator
HOLD /
INA
INB
+12V
0V
RESET
8
9
10
11
12
1
2
3
4
5
■ Relay double output
HOLD /
INA
INB
+12V
0V
HIGH LOW
RESET
8
9
10
11
12
H
L
1
2
3
4
5
CONTACT OUT:
250 VACᜠ 3 A, 30 VDCᜡ 3 A
RESISTIVE LOAD
Specifications
Series
Input signal
01)
Voltage input
No-voltage input
Display method
Character size
Prescale
Hysteresis
Display cycle
Display range
Contact control output Relay
Type
Capacity
Solid-state control output NPN open collector
Type
Capacity
Approval
Unit weigth (package) ≈ 168 g (≈ 243 g)
01) Standard duty ratio 1:1
02) Operation mode F7, F8: ≤ 1 kHz (pulse width: ≥ 500 ㎲)
03) The hysteresis setting range varies according to the decimal point setting position.
04) Only available operation mode F2, F14
Power supply
Power consumption
External power supply ≤ 12 VDCᜡ ±10 % 80 mA
Memory retention
Relay life cycle
Insulation resistance
Dielectric strength
Noise immunity
Vibration
Vibration
(malfunction)
Shock
Shock (malfunction)
Ambient temperature
Ambient humidity
Operation mode
F1
Frequency / revolutions / speed
F2
Passing speed
F3
Cycle
F4
Passing time
F5
Time interval
F6
Time differential
F7
Absolute ratio
F8
Density
F9
Length measurement 1
F10
Interval
F11
Accumulation
Addition / subtraction-
F12
individual input
Addition / subtraction-phase
F13
difference input
F14
Length measurement 2
13
14
Mode Setting
15
[MODE]
16
RUN
17
[MODE] 2 sec
01) Press [▲], [◀] key or [MODE] key for 1.5 sec after entering parameter: select parameter groups.
6
7
Parameter Setting
SOURCE
• Some parameters are activated / deactivated depending on the model or setting of
other parameters. Refer to the description of each parameter.
• The parameter and setting value are cross-displayed on the display part.
• If any key is not entered for 60 sec in each parameter, it returns to RUN mode.
13
14
• [MODE] key: Saves current setting value and moves to the next parameter.
[◀] key: Checks fixed value / Changes setting digits.
[▲], [◀] key: Changes setting values.
15
■ Parameter 0 group
16
17
Parameter
Max.
P0-1
monitoring
value
6
7
Min.
P0-2
monitoring
value
SOURCE
MP5M-□N
MP5M-□1
Solid state input 1: ≤ 50 kHz (pulse width: ≥ 10 ㎲)
Solid state input 2
: ≤ 5 kHz (pulse width: ≥ 100 ㎲)
02)
Contact input: ≤ 45 Hz (contact: ≥ 12 VDCᜡ 5 mA, pulse width: ≥ 11 ms)
Input impedance: 3.9 kΩ, [H]: 4.5 - 24 VDCᜡ, [L]: 0 - 1 VDCᜡ
Short-circuit impedance: ≤ 80 Ω, residual voltage: ≤ 1 VDCᜡ,
open-circuit impedance: ≥ 100 kΩ
7-segment LED (zero blanking method)
W 4 × H 8 mm
0.0001 × 10
to 9.9999 × 10
-9
9
-
0 to 9999
03)
OFF
, 0.05, 0.5, 1, 2, 4, 8 sec (same as update output cycle)
04)
-19999 to 99999
-
1c × 1
250 VACᜠ 3 A, 30 VDCᜡ
-
3 A resistive load
-
× 1
-
≤ 30 VDCᜡ 100 mA
ᜢ ᜧ ᜫ
≈ 181g (≈ 256g)
AC voltage
AC / DC voltage
100 - 240 VACᜠ ᜠ ± 10 %
24 VACᜠ ± 10 % 50 / 60 Hz,
50 / 60 Hz
24 - 48 VDCᜡ ± 10 %
≤ 9 VA
AC: ≤ 6.5 VA, DC: ≤ 5 W
Number of inputs: 100,000 operations (non-volatile semiconductor memory type)
Mechanical: ≥ 5,000,000 operations
Electrical: ≥ 100,000 operations (250 VACᜠ 3 A resistive load)
≥ 100 MΩ (500 VDCᜡ megger)
2,000 VACᜠ 60 Hz for 1 min
± 2 kV the square wave noise (pulse width: 1㎲) by the noise simulator
0.75 mm double amplitude at frequency of 10 to 55 Hz in each X, Y, Z
direction for 1 hour
0.5 mm double amplitude at frequency of 10 to 55 Hz in each X, Y, Z
direction for 10 min
300m / s² (≈ 30G) in each X, Y, Z direction for 3 times
100m / s² (≈ 30G) in each X, Y, Z direction for 3 times
-10 to 50 ℃, storage: -20 to 60 ℃ (no freezing or condensation)
35 to 85 %RH, storage: 35 to 85 %RH (no freezing or condensation)
Measurement range
0.0005 Hz to 50 kHz
0.01 to max. of each time range F.S. ± 0.01 % rdg ± 1-digit
0.0005 Hz to 50 kHz
0 to 99999
-19999 to 99999
0 to 99999
→
Parameter 0 group
[MODE]
→
Parameter group
[MODE] 3 sec
01)
Display
Default
Setting range
hPEK 99999
• Reset (PV): [◀] key for over 2 sec
lPEK `9999
MP5M-□2
1a × 2
250 VACᜠ 3 A, 30 VDCᜡ
3 A resistive load
× 2
≤ 30 VDCᜡ 100 mA
≈ 190 g ( ≈ 265 g)
Measurement accuracy
(23 ± 5 ℃)
F.S. ± 0.05 % rdg ± 1-digit
F.S. ± 0.05 % rdg ± 1-digit
-
→
RUN
→
Display
condition
P1-1 Input
operation
mode:
except F11,
F14