Autonics BD Series Panduan Produk - Halaman 6

Jelajahi secara online atau unduh pdf Panduan Produk untuk Sensor Keamanan Autonics BD Series. Autonics BD Series 6 halaman. Laser displacement sensors amplifier unit
Juga untuk Autonics BD Series: Manual (14 halaman), Panduan Produk (5 halaman), Panduan Produk (3 halaman)

Autonics BD Series Panduan Produk
Test for Robot Type Extension Cable
In the following each test environment, repeat the test until the sample is electrically
disconnected, and then check the number of times.
■ Flexure test
Test environment
Sample cable
Bar
Flexure angle (R)
Weight (W)
■ Torsion test
Test environment
Rotating chuck
Drive part
Sample cable
Length (L)
Conditions
Flexure angle (θ) 180º
Weight (W)
1 kg
Length (L)
50 mm
60 times / minute
Flexure speed
• 1 round trip is done
once.
■ U bending test
Test environment
Length (L)
Moving part
Fixing part
Cable bear + Sample cable
Conditions
Length (L)
400 mm
Flexure radius (R) 18 mm
60 times / minute
Flexure speed
• 1 round trip is done
once.
Conditions
Flexure angle (θ) 90º
Weight (W)
1 kg
Flexure radius (R) 30 mm
60 times / minute
Flexure speed
• 1 round trip is done
once.
Result
≈ 32,000,000 times
Slider
Weight
(W)
Result
≈ 30,000,000 times
Flexure radius (R)
Result
≈ 42,000,000 times
18, Bansong-ro 513Beon-gil, Haeundae-gu, Busan, Republic of Korea, 48002
www.autonics.com | +82-2-2048-1577 | [email protected]
-